Monessen Hearth WC400 Homeowner's Installation And Operating Manual

Wr series; wc series
Hide thumbs

Advertisement

Woodburning Fireplace
948
SR cover
11/18/97
For use in U.S./Canada
Underwriter's Laboratories Report No. MH6018
DO NOT DISCARD THIS MANUAL: Retain for future use.
WR/WC Series
948
SC cover
11/18/97
For Models:
WC400, WR400
WC500, WR500
Homeowner's Installation
and Operating Manual
20014528 12/09 Rev. 3

Advertisement

Table of Contents
loading

  Related Manuals for Monessen Hearth WC400

  Summary of Contents for Monessen Hearth WC400

  • Page 1 Woodburning Fireplace SR cover 11/18/97 SC cover 11/18/97 For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use. For Models: WC400, WR400 WC500, WR500 Homeowner's Installation and Operating Manual 20014528 12/09 Rev. 3...
  • Page 2: Table Of Contents

    Description The WR/WC Series fireplaces are solid fuel, woodburn- ing premium fireplaces. The WR400/500 are radiant clean-face models and the WC400/500 are circulating models with removable grilles (louvres). Both models are fully insulated fireplaces. Precautions...
  • Page 3: Specifications And Framing

    Outside Gas Line Access 11" (279mm) 8" (203mm) 15 " (391mm) Fig. 1 WR400 Series specifications and framing. WC400 Series Woodburning Fireplace — Circulating Model 48 " (1232mm) 1/2" (13mm) 1/2" 39 " (1006mm) Outside Air Gas Line Access 11"...
  • Page 4 WR / WC Series Woodburning Fireplace WR500 Series Woodburning Fireplace 50" (1270mm) 1/2" (13mm) 1/2" 39 " (1006mm) Outside Gas Line Access 11" (279mm) 8" (203mm) 15 " (397mm) Fig. 3 WR500 Series specifications and framing. WC500 Series Woodburning Fireplace — Circulating Model 50"...
  • Page 5: Parts Identification

    Front Width back Width FP1531 WR/WC400 31¹⁄₈" 19⁷⁄₈" hearth dimensions (791 mm) (505 mm) 9/04 djt WR/WC500 36³⁄₄" 22⁷⁄₈" (934 mm) (581 mm) Fig. 4a Hearth dimensions. Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation.
  • Page 6: Chimney Requirements

    Illustration Key The following safety rules apply to offset installations (letters correspond with il- lustration above): A. Height of the chimney is measured from the hearth to the chimney exit. WR/WC400 WR/WC500 Maximum: 90'0" 90'0" Minimum: Without Elbows 12' 6"...
  • Page 7: Planning Information

    Preplanning an installation is very important to ensure safety and to save time and money. An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting the Fireplace A fireplace may only be mounted on the following sur- faces: 1.
  • Page 8: Installation

    WR / WC Series Woodburning Fireplace Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30' (9m) with SK8 chimneys or 20' (6m) with 3-wall chimneys.
  • Page 9 Framing Framing can be constructed before or after the fireplace is set in place, however, most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications.
  • Page 10 WR / WC Series Woodburning Fireplace Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9¹⁄₄" (235mm). Mark a spot on the ceiling directly above the fireplace. Draw a line parallel to the back wall through this mark.
  • Page 11 The following table gives firestop spacer model num- bers: Angle of Chimney at Ceiling Size of Chimney Vertical 8" Flue SKFS2A "SK" Series 14¹⁄₂" x 14¹⁄₂" (368mm x 368mm) (368mm x 648mm) 8" Flue FS2A "S" Series 3-Wall 17¹⁄₂" x 17¹⁄₂" (445mm x 445mm) (454mm x 753mm) Fig.
  • Page 12 WR / WC Series Woodburning Fireplace Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer. Installing the Firestop Spacer in the Ceiling Hole A firestop spacer is used to keep pipe spaced properly and required for safety.
  • Page 13 NOTe: In the U.S., it is a good idea, although not al- ways required, to install an attic insulation shield where blown-in insulation is planned to be used in the attic. Install the attic insulation shield with the flanges on its base extending down into the framing hole.
  • Page 14 WR / WC Series Woodburning Fireplace Installing Top Housing or Termination Follow the installation instructions provided with the chimney termination you have selected. Installing Chimney In a Chase Refer to Page 5, Figure 5 for an illustration of a typical chase installation.
  • Page 15 Mantel Clearance - Radiant Model - No Noncombustible Facing Material Combustible Man- Combustible tel and Trim Mantel and 12" Trim (305mm) Finished Wall Max. 1 " Header (38mm) 12" Standoff (305mm) Noncombustible Min. Material Radiant Sur- round Face Fireplace Open- * Minimum width from top of sur- round to bottom of screen rail Fig.
  • Page 16 (minimum R Value = 1.85) between decorative noncombustible rigid covering and combustible wall. Minimum height and width is 40" x 40". ** Dimension/degree of angle will vary depending on thickness of noncombustible surround facing. WR/WC400 16" 406 mm 305 mm WR/WC500 20"...
  • Page 17 COMMON MATERIALS AND FACTORS MATERIAL EH2416 0.458 1.09 (MHSC) Common Brick 0.10 R Value is for 1/2 inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thickness of Listed Material Fig. 24 Hearth extension material factors. WARNINg: HeARTH eXTeNSION MUST be IN- FP533ADD Addendum STALLeD IN ACCORDANCe WITH FIgURe 23 AND...
  • Page 18 WR / WC Series Woodburning Fireplace Installing Line for gas Logs MHSC fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (MHSC manufactures a wide variety of gas logs for use in MHSC fireplaces.) Be sure to have the appliance installed in accordance with building codes.
  • Page 19: Replacement Parts

    MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. WR400/500, WC400/500 SeRIeS Ref. Description Damper Weld Assembly Damper Bracket Screen Rod (two per fireplace) Pull Screen (two per fireplace)
  • Page 20: Accessories

    Glass Door — Standard Fan Kit Variable Speed Control Outside Air Termination Chimney Adapter Hearth Extension Insulation Grate WR/WC400/500 Hearth Patch Compound Contact your MHSC distributor or dealer for finishing Marble and Mantels, available in a wide selection of styles. Accessories Description...
  • Page 21 U.S. Component Round Top Termination Top used to terminate chimney at roof. (Flashing not included.) Round Top Termination - Top used to terminate chimney at chase. Extended (Flashing not included.) Flashing Metal finishing required around Contemporary Termination to prevent rain leakage. Square Termination Top housing of simulated brick pattern Housing...
  • Page 22 WR / WC Series Woodburning Fireplace (Chimney Components con't.) Canada Component Chimney Collar Enclosure Attic Insulation Shield SK8 Chimney Sections 45 Chimney Elbows Description Installs on the "over the chimney collar" of the fireplace; provides outside air to assist in cooling the chimney system.
  • Page 23 What is Covered and For How Long Five-Year Coverage: For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replace any defective part of this fireplace or components, or refund to you a sum not to exceed the factory retail price in effect at the time of purchase.
  • Page 24 MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com 20014528 10/08 Rev. 2...