Canterbury Freestanding Installation Instructions - Cannon Canterbury CANTFS-SDE Instruction Manual

Freestanding stove
Table of Contents

Advertisement

CaNTErbury frEESTaNDiNg iNSTallaTiON iNSTruCTiONS

Overview
1. This appliance MuST be installed by a suitably
licensed person only.
2. This appliance shall be installed in accordance with
these manufacturer's installation instructions, local
gas fitting regulations, municipal building codes,
electrical wiring regulations, and AS5601 the
Australian Standard for gas installations.
refer also AS5601 for gas pipe sizing tables.
This heater is not suitable as a fire place insert.
Installation Instructions
Avoid installing the heater in front of the shortest wall of
a high pitched roof as the possibility of down draught will
cause problems with the heater operation and may not
be fixable.
Ensure there are no obstructions around the cowl
(i.e. overhanging tree branches).
refer to the Australian Standard gas Installations AS
5601: for 'location of flue terminal'.
Terminating a flue in a roof space is not permitted.
To avoid any unnecessary delays and inconvenience
to your customer, please contact Technical Support on
1300 727 421 if the installation is unusual or you have
any concerns with the installation and/or heater operation
before the installation commences.
Make sure that the heater is fully commissioned and be
certain to test the integrity of the flue operation, taking
into account any influences created by range-hoods,
exhaust fans, central heating,etc.
Any service request resulting from incorrect installations
are not covered by our warranty conditions and these
will result in charges, usually to the end user, so please
be sure that the installation and commissioning has
been satisfactorily carried out before calling for any
warranty service.
Please ensure that the end user is fully instructed on
how to operate the heater.
Clearances
1. Ensure the minimum clearances to combustible
construction are maintained during installation,
including adequate space for the proper operation
and servicing of the heater.
For clearances to curtains and furnishings refer to
warning 4 & 5 on page 5.
For minimum clearances refer FIG 4 and FIG 5.
2. remove the carton from the heater and lift heater from
wooden pallet.
Check that the heater is suitable for the gas available.
refer to the data label located on the left side panel
near the electronic control box.
(Please dispose of packaging appropriately, keep it
away from children).
3. Prepare electrical and gas connections, a 10 Amp
switch socket needs to be located within 1.5m of
the heater.
4. Fit rear spacers as per FIG 5.
100 mm minimum
side clearance
1m min.
fig 4
40 mm minimum
back clearance
Flue outlet
115 mm from
rear
rear spacer
fig 5
Cannon Canterbury Freestanding | 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Canterbury cantfs-sdeeb

Table of Contents