Summary of Contents for Cannon Canterbury CANTFS-SDE
Page 1
Sharing a lifetime of cosy moments Canterbury Freestanding Instruction Manual Please read this manual before installing and using this heater. Model: CANTFS-SDEEB Please leave instruction manual with the owner Distributor This appliance is designed, manufactured and distributed by: Tel: 1300 727 421...
This Warranty against defects for your newly purchased c. will not apply where the defect in or failure of Cannon product is proudly prepared by Sampford IXl Pty the product is attributable to misuse, abuse, ltd of 421 Smith Street, Fitzroy, vIC 3065, accident or non-observation of the manufacturer’s...
Page 4
11. Sampford IXl and its Authorised Service Dealers reserve the right to seek reimbursement of any costs incurred by them should your Cannon product be found to be in good working order. Privacy The privacy of your personal information has always been important to us.
Cannon heater and other appliances. procedures, or consult with place of purchase, a licensed plumber, a gas supplier or the CANNON Refer to Australian Standard Gas Installations AS 5601. distributor listed in this manual.
High wind gusts can affect the heaters flueing and ON / OFF switch the heater off. If this happens, restart the heater as normal. If the problem persists contact Sampford IXL. NORMAL BOOST fig 1 fig 2 6 | Cannon Canterbury Freestanding...
OPTiONal aCCESSOriES Every Cannon heater brings you the optional convenience of being controlled via a remote thermostat. For added convenience the heater can now be connected to a home automation system, such as C-bus. This allows the heater to be turned on or off remotely (normal heat setting only).
FIG 3 Please note: The data label is located on the left hand side panel near the electronic control box. 100 mm min side clearance 650 mm 425 mm fig 3 Back view and Side view 8 | Cannon Canterbury Freestanding...
Please ensure that the end user is fully instructed on how to operate the heater. fig 4 40 mm minimum 1m min. back clearance Flue outlet 115 mm from rear rear spacer fig 5 Cannon Canterbury Freestanding | 9...
FIG 8. This heater can be placed on either combustible or non combustible floor surfaces. fig 7 Top: rearward sloping frame Bottom: vertical edge fig 8 10 | Cannon Canterbury Freestanding...
If bends are used, they must fit inside flue on downwards ends. use no more than two 45° bends in the total flue run and maintain at least 250mm of straight flue pipe between the bends fig 10 Cannon Canterbury Freestanding | 11...
Connect incoming gas supply pipe to 1 / 2 ” compression fitting at rear of appliance. For inlet position refer FIG 11. Solid copper pipe to be used only. Heater is not to be connected using a flexible hose. 110mm 125mm fig 11 12 | Cannon Canterbury Freestanding...
#3 log. refer FIG 16. fig 13 fig 14 3. refit the inner glass, making sure not to over tighten the screws. 4. refit the front glass surround. fig 15 fig 16 Cannon Canterbury Freestanding | 13...
• Check that the flue is operating correctly. Hold If the heater still does not operate to specification refer to the troubleshooting chart on page 18, or contact Sampford IXl in your state. adjust fig 21 14 | Cannon Canterbury Freestanding...
1. unplug both fan and main loom from wiring harness. 2. remove bracket securing electronic controller in position. 3. replace electronic controller and refit in reverse order. Ignition Module gas valve Electronic Controller fig 22 Cannon Canterbury Freestanding | 15...
Page 16
6 - 8mm. Check for gas tightness. Flame sense electrode must be in constant flame. For log placement refer page 13 of this manual. To Replace The Power Cord Contact Sampford IXl service department. fig 25 Securing the burner bed 16 | Cannon Canterbury Freestanding...
Make sure that the pressure switch wires are connected correctly. One wire should be to C (Common) and the other should be to NO (Normally Open). If it still doesn’t work after checking the above, change the pressure switch. 18 | Cannon Canterbury Freestanding...
Page 19
• Check that there is gas to the inlet of the gas control. Fuse blowing. • If the fuse continues to blow check the solenoid coils for a signs of them being shorted. • Check the fan and wiring for short circuit. Cannon Canterbury Freestanding | 19...
Page 20
For service to this appliance or spare parts Gmk 10025 contact the CANNON distributor: Gmk 10030 AS4553:2008 Sampford IXL – Spare Parts Phone: 1300 727 421 Part Number: Fax: 1300 727 425 Email: aftersalesservice@sampfordixl.com.au F3842_B 20 | Cannon Canterbury Freestanding...