Operation - Cannon Canterbury CANTFS-SDE Instruction Manual

Freestanding stove
Table of Contents

Advertisement

OPEraTiON

Operating Instructions
Plug the power cord into the switch socket and turn
on the power to the heater (FIG 1). Alternatively, switch
on the isolation switch and circuit breaker at the main
switchboard if the heater has fixed wiring. refrain from
using an extension cord.
user controls FIG 2.
When there is power available to the heater and it is in the
off or Standby mode, a red lED located inside the ON/
OFF button will flash twice and will extinguish for approxi-
mately 3 seconds and then repeat this cycle continuously.
To turn the heater ON press the ON/OFF button once.
• The LED will illuminate and an audible beep will sound
but there will be approximately 5 seconds delay
before the ignition system commences. On success-
ful ignition the heater will operate on low Fire and
low Fan for approximately 3 minutes then will switch
to selected setting (if already chosen, otherwise it will
switch to NOrMAl setting automatically).
• The LED will extinguish approximately 30 seconds
following the ignition startup.
• Select the desired heating level by pressing the LOW,
NOrMAl or BOOST button once as required.
• LOW is LOW heat and LOW speed fan. BOOST is
High heat and High speed fan.
• To turn the heater OFF press the ON/OFF button
once. An audible beep will sound twice to indicate
the heater is off. The burner will extinguish but the fan
will continue to operate for approximately 3 minutes.
remember that the fan will continue to operate for
approximately 3 minutes after the OFF button has
been pressed but you can turn the heater ON again
without having to wait for the fan to stop operating.
• If the ignition system fails to ignite or keep the burner
alight, the system will beep 4 times and go into
safe shutdown mode. It will beep 4 times every 30
seconds to alert you to the fact. Press the ON/OFF
button once to restart the heater during this time.
you MuST wait at least 5 minutes before trying to
turn the heater on again if there have been several
attempts to ignite the heater without success.
fig 1
6 | Cannon Canterbury Freestanding
• If there is an interruption to the power supply the
heater will fail safely and switch off. When the power
supply has been restored you MuST wait at least 5
minutes before turning the heater ON.
Cleaning
All cleaning should be carried out when the heater is
cold. Normally the heater should only need wiping with
a lint-free damp cloth. Any stubborn stains can be
removed with a nonabrasive spray on cleaner. If an
abrasive cleaner is used the paint finish will be damaged.
For heaters fitted with the glass front: All cleaning should
be carried out when the heater is cold. Clean the outer
glass with a mild liquid or spray on glass cleaner. Do not
use harsh abrasive cleaners or sharp metal scrapers to
clean the heater glass front since they can scratch the
surface, which may result in shattering of the glass.
Internally the heater should only be cleaned by an
authorised service person listed in this manual.
If your heater requires attention contact your supplier
or authorised service person listed in this manual.
Flame Characteristics
The heater flame should be stable, not lifting from
the burner. The logs should glow after approximately
15 minutes operation on BOOST setting.
The heater is designed to operate with luminous flames
and may exhibit slight carbon deposit on the logs. If there
is any excess carbon build-up on logs, or the burner
flame is unstable, contact Sampford IXl in your state.
Important
The appliance MUST be serviced at least annually
by an authorised service person. This maintenance
cost is not covered under the warranty terms and
conditions. More frequent cleaning may be required
due to excessive lint build-up from carpeting,
bedding materials, pet hair, etc.
It is imperative that control compartments, burners
and circulating air passage ways of the appliance
be kept clean.
Do not use this heater if the glass is cracked or with
the safety screen removed.
Do not use heater with broken or missing logs.
High wind gusts can affect the heaters flueing and
ON / OFF
switch the heater off. If this happens, restart the
heater as normal. If the problem persists contact
LOW
Sampford IXL.
NORMAL
BOOST
fig 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Canterbury cantfs-sdeeb

Table of Contents