Download Print this page

Sanyo HEC-DR5000 Service Manual page 30

Chair type massager
Hide thumbs Also See for HEC-DR5000:

Advertisement

Replacement Procedure
(18) Replacement of Limit switch (Elevation)
1, Remove one cover (shaft screw) set screw
and take off the cover (shaft screw).
2, Take off the holder (limit switch).
3, Disconnect the limit switch.
Limit switch
Holder (limit switch)
Cover set screw
(19) Replacement of Volume rotary
* Take off the motor (strength) in advance.
1, Remove one cam (pressure) set screw and
take off the cam (pressure).
2, Loosen a nut off volume fixation and take
off the volume rotary.
3, Disconnect the volume rotary.
Volume rotary
Nut
Jul./2005 Printed in Japan
Photo-35
Photo-35
Photo-35
Cover (shaft screw)
Photo-35
Photo-36
Photo-36
Photo-36
Cam set screw
Cam (pressure)
Photo-36
(20) Replacement of Transfommer
1, Disconnect the transformer connector.
2, Remove two cover (transformer) set screws
and take off the cover (transformer).
Cover (transformer)
Transformer connector
3, Remove transformer set serews.
4, Remove cord bushing.
Transformer
Cord bushing
- 30 -
HEC-DR5000
(GENERAL)
Photo-37
Photo-37
Cover set screw
Photo-37
Photo-38
Photo-38
Transformer set screw
Photo-38
SANYO Electric Co.,Ltd
Osaka, Japan

Advertisement