Download Print this page

Sanyo HEC-DR5000 Service Manual page 20

Chair type massager
Hide thumbs Also See for HEC-DR5000:

Advertisement

Air-Bag Operation Confirmation Procedure
Start-up of Examination Mode
Turn ON the POWER switch at the rear of the massager while simultaneously pressing the
POSITION ADJUST "UP" and "DOWN" buttons on the remote controller (This operation should
be started with the POWER switch turned OFF).
When the examination mode is started up, both a backrest and a foot rest move slightly and
come to a stop.
LOWER BODY STRENGTH adjusting button
POSITION ADJUST "UP" and "DOWN" buttons
Air-Bag Operation Confirmation
Press either "WEAK" or "STRONG" button of the LOWER BODY STRENGTH adjustment on
the remote controller.
Check if the air-bag inflates sequentially as shown below.
* If there are any problems, check air leakage, breakage of air hoses, and the air-bag.
5
8
8
7
7
5
5
6
6
4
4
2
2
1
3
3
1
4
4
(Simultaneously press)
POWER switch "ON"
1, Foot pinching, outside
2, Foot pinching, inside
3, Foot shiatsu, middle
4, Foot shiatsu, back and forth
5, Leg pinching, inside, outside
5
6, Leg shiatsu, lower
7, Leg shiatsu, upper
8, Thigh, right, left
- 20 -
HEC-DR5000
(GENERAL)
OPEN
LOCK
ON
OFF
POWER