Replacement Procedure
(6) Replacement of Remote Control
1, Remove each cord processing and
disconnect the cords.
2, Remove nine remote control case set screws
and take off a remote control case (lower).
Remote control case (lower)
3, Remove two PCB (remote control) set screws
and take off the PCB (remote control)
4, Disconnect the interconnecting connector
CN1 of the connector (remote control).
PCB (remote control)
Connector (remote control)
Photo-12
Remote control case set screws
Photo-12
Photo-13
Photo-13
PCB set screws
CN1
Photo-13
(7) Replacement of Sensor
1, Remove each cord processing and
disconnect the cords.
2, Remove two sensor case set screws and
take off a sensor case (upper).
Sensor case (upper)
Sensor case set screws
3, Remove one PCB (sensor) set screw and
take off the PCB (sensor).
4, Disconnect the interconnecting connector
CN703 of the connector (sensor).
PCB set screw
Connector(sensor)
- 24 -
HEC-DR5000
(GENERAL)
Photo-14
Photo-14
Photo-15
Photo-15
PCB (sensor)
CN703
Photo-15