VX-2100
VX-2200
PERATING
M
ANUAL
VX-2100
VX-2200

Advertisement

Table of Contents
loading

Summary of Contents for Vertex Standard VX-2100 Series

  • Page 1 Winchester, Hampshire, SO23 0LB, U.K. VERTEX STANDARD HK LTD. Unit 1306-1308, 13F., Millennium City 2, 378 Kwun Tong Road, Kwun Tong, Kowloon, Hong Kong VERTEX STANDARD AUSTRALIA PTY., LTD. Tally Ho Business Park, 10 Wesley Court, East Burwood, VIC, 3151...
  • Page 2 We’re glad you joined the VERTEX STANDARD team. Call on us anytime, because communications is our business. Let us help you get your message across.
  • Page 3 The VX-2100 allows up to 8-channel memories. The VX-2200 allows up to 128- channel memories which can each be programmed with an 8-character channel name.
  • Page 4: Front Panel

    Front Panel Important! - All buttons located on the Front Panel are Programmable Function (PF) Buttons, configured according to your network requirements and programmed by your VERTEX STANDARD dealer. The instructions below describe a typically- configured radio. VOL/PWR Knob Turn this control clockwise to turn the radio on and to increase the volume.
  • Page 5 Transceiver Status Indicator The “A” and “B” indicators show current transceiver status, which can be cus- tomized via programming by your VERTEX STANDARD dealer to meet your communications/network requirements. The possible “A” and “B” displays are explained below. TX/BUSY Indicator Indicates transceiver’s Transmit/Receive Status...
  • Page 6 Front Panel Important! - All buttons located on the Front Panel are Programmable Function (PF) Buttons, configured according to your network requirements and programmed by your VERTEX STANDARD dealer. The instructions below describe a typically- configured radio. VOL/PWR Knob Turn this control clockwise to turn the radio on and to increase the volume.
  • Page 7 Receiver Monitor Low Transmt Power Mode “ON” “Talk-Around” is enabled “AUX A” Port is activated Priority Channel “Encryption” is enabled Channel Group Number RSSI Indicator (four steps) “Group Scan” is enabled 8 Character Alpha-numeric Display VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 8: Controls And Connectors

    An external loudspeaker may be connected to this 2-contact, 3.5-mm mini-phone jack. Caution: Do not connect either wire of this line to ground, and be certain that the speaker has adequate capability to handle the audio output (12 W) from the radio. VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 9: Switching Power On/Off

    If CTCSS or Digital Coded Squelch (DCS) Lockout has been programmed on a channel, the radio can transmit only when there is no carrier being received or when the carrier being received includes the correct CTCSS tone or DCS code. VX-2100/-2200 S ERIES PERATING...
  • Page 10: Operation

    DVANCED PERATION Programmable Function (PF) Buttons The VX-2100/-2200 Series includes six Programmable Function (PF) Buttons. The PF button functions can be customized, via programming by your VERTEX STAN- DARD dealer, to meet your communications/network requirements. Some features may require the purchase and installation of optional internal accessories. The pos- sible PF button programming features are illustrated below, and these functions are explained on the pages to follow.
  • Page 11: Advanced Operation

    Speed Dial Public Address EXT. ACC1 EXT. ACC2 Direct CH#1 Direct CH#2 AF Min Vr Lone Worker HA ( Horn Alert ) Key Lock 1: These functions cannot assign to VX-2100 2: Requires optional unit VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 12: Description Of Operating Functions

    (repeatedly) upward or downward through the channels. OWN ( This function is only available in the VX-2200 ) ROUP Press (or press and hold) the assigned programmable key to select a different group of channels VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 13: Channel Scan ( Scan )

    Press (or press and hold) the assigned programmable key to delete the Current Memory channel from the Scanning. In the VX-2100, when you delete a channel, the decimal point “.” will disappear from the Channel Number Indicator. To restore a particular channel to your scan- ning list, press (or press and hold) the assigned programmable key again;...
  • Page 14: Group Scan

    The scanner will search the two channels; it will pause each time it finds a channel on which someone is speaking. To stop Dual Watch: Press (or press and hold) the assigned programmable key. Operation will revert to the “Dual Watch Start” channel. VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 15 “Low Power” mode. Press (or press and hold) the key again to return to “High Power” operation when in difficult terrain. In the VX-2200, when the radio’s transmitter is set to “Low Power” mode, the “ ” icon will be indicated on the display. VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 16 MERGENCY The VX-2100/-2200 series include an “Emergency” feature which may be useful if you have someone monitoring on the same frequency as your transceiver’s channel. Press (or press and hold) the assigned programmable key to initiate an emergency call.
  • Page 17: Public Address

    Press (or press and hold) the assigned programmable key to use the transceiver as a PA amplifier. In the VX-2200, when you enable this function, a tone sounds and “PUBLIC A” will appear on the display. The public address can be used even while scanning and receiving a call. VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 18: Lone Worker

    Tone or DTMF signaling, horn alert will be activated and your vehicles horn will sound. In the VX-2200, when you turn the Horn Alert “ON,” a tone will sound and the “HORN ALT” will appear on the display. VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 19: Arts (Auto Range Transpond System)

    “In” will be displayed again on the LCD for 2 seconds . : The VX-2100 only. DTMF Paging System ( Requires the optional FVP-25 Encryption/DTMF Pager Unit ) This system allows paging and selective calling, using DTMF tone sequences.
  • Page 20: User Set Mode

    DIS: Disables the disabling the Encryption Unit. Sets the minimum Audio Volume level. AF MINVR BEEP VR Sets the Beep Volume level. Sets the LCD Contrast level. CONTRAST DIMMER Sets the brightness of the LCD backlighting. : Requires optional unit VX-2100/-2200 S ERIES PERATING ANUAL...
  • Page 21: Optional Accessories

    Availability of accessories may vary; some accessories are supplied standard per local requirements, others may be unavailable in some regions. Check with your VERTEX STANDARD Dealer for changes to this list. There are no owner-serviceable parts inside the transceiver. All service jobs must be referred to an authorized VERTEX STANDARD Service Represen- tative.
  • Page 22 In EU countries, please contact your local equipment supplier representative or service center for information about the waste collection system in your country. Part 15.21: Changes or modifications to this device not expressly approved by Vertex Standard could void the user’s authorization to operate this device. VX-2100/-2200 S...
  • Page 23: Declaration Of Conformity

    VX-2100-D0-25 VX-2200-D0-25 VX-2100-G6-25 VX-2200-G6-25 Manufacturer: Vertex Standard Co., Ltd. Address of Manufacturer: 4-8-8 Nakameguro Meguro-Ku, Tokyo 153-8644, Japan Applicable Standards: This equipment is tested and conforms to the essential requirements of directive, as included in following standards. EN 300 086-2 V1.3.1 Radio Standard: EN 300 113-2 V1.4.2...
  • Page 24 Copyright 2011 VERTEX STANDARD CO., LTD. All rights reserved. No portion of this manual Printed in China may be reproduced without the permission of VERTEX STANDARD CO., LTD.

This manual is also suitable for:

Vx-2200 series

Table of Contents