Cautions and Limitations
A. Not for use in atmospheres containing less than 19.5% oxygen.
B. Not for use in atmospheres immediately dangerous to life or health.
C. Do not exceed maximum use concentrations established by
regulatory standards.
F. Do not use respirator if airflow is less than four cfm (115 lpm) for tight
fitting face pieces or six cfm (170 lpm) for hoods and/or helmets.
I. Contains electrical parts that may cause an ignition in flammable or
explosive atmospheres.
J. Failure to properly use and maintain this product could result in injury
or death.
L. Follow the manufacturer's user instructions for changing cartridges and/
or filters.
M. All approved respirators shall be selected, fitted, used and maintained in
accordance with MSHA, OSHA and other applicable regulations.
N. Never substitute, modify, add or omit parts. Use only exact Bullard
replacement parts in the configuration as specified by the manufacturer.
O. Refer to User's Instructions and/or maintenance manuals for information
on use and maintenance of these respirators.
P . NIOSH does not evaluate respirators for use as surgical masks.

Table of Contents

Warnings, Cautions and Limitations ............................................................... 1
Principle of Operation / Battery Pack ........................................................... 2
Pre-Operational Inspection ............................................................................. 3
Mounting the Breathing Tube ........................................................................... 3
Checking Air Flow / Air-Purifying Elements .................................................... 4
Donning the Blower / Low Battery Alarm ....................................................... 5
Low Battery Alarm / Doffing the Blower ........................................................ 6
Troubleshooting ............................................................................................... 7
EVA Series Powered Air-Purifying Respirator
(Incorporating the Bullard FAMB® Series Half Face Mask)
Use strictly in accordance with instructions, labels and limitations
pertaining to the EVA Series respirator.
1. The EVA Series respirator does not supply oxygen. Use only in adequately
ventilated areas containing at least 19.5% oxygen.
2. Do not use when concentrations of contaminants are immediately
dangerous to life or health (IDLH).
This term is defined in 29CFR 1910.134 (b).
3. Do not use these respirators for respiratory protection during abrasive
blasting or clean up.
4. Do not use in circumstances where the airborne concentration level
of contaminant exceeds maximum use concentration for this type of
respirator as established by regulatory standards.
5. Leave area immediately if:
• Breathing becomes difficult
• Dizziness or other distress occurs
• You taste or smell the contaminant
• Unit becomes damaged
• Battery alarm activates
• Low Flow alarm activates
6. This apparatus must not be worn with the blower unit switched off. If the
blower is switched off, a rapid build-up of carbon dioxide and depletion of
oxygen may occur, which could result in death or serious injury.
7. Never alter or modify this respirator. Use only Bullard NIOSH-approved
EVA Series components and replacement parts for this respirator.
8. This device is not immune to highly powered RFI/EMI emissions.
Failure to follow these warnings could result in death or serious injury.
NIOSH Approval Label .................................................................................... 8
Inspection / Cleaning / Storage...................................................................... 9
Fit Testing / Warranty / Return Authorization .............................................. 10
FAMB Diagram ............................................................................................... 11
Ordering Information ..................................................................................... 12
www.bullard.com
Blower Assembly User Manual
Powered Air-Purifying Respirator with OV-AG-HE Filter
Cartridges for organic vapors, chlorine, hydrogen chloride,
sulfur dioxide, chlorine dioxide, hydrogen fluoride and
WARNING
Powered Air-Purifying Respirator
with High Efficiency (HE) Filters -
Approval No. TC-21C-0846
particulates -
Approval No. TC-23C-2511

Advertisement

Table of Contents
loading

Summary of Contents for Bullard EVA Series

  • Page 1: Table Of Contents

    EVA Series respirator. B. Not for use in atmospheres immediately dangerous to life or health. 1. The EVA Series respirator does not supply oxygen. Use only in adequately C. Do not exceed maximum use concentrations established by ventilated areas containing at least 19.5% oxygen.
  • Page 2: Principle Of Operation / Battery Pack

    Details for these functions are available in the charger user The EVA Series Blower is equipped with two alarms: A 77 db continuous manual (upon special order). alarm will sound when the air flow reaches approximately 115 lpm and a 77db intermittent chirp alarm will activate to indicate that the battery has approximately 15 minutes of remaining capacity.
  • Page 3: Pre-Operational Inspection

    If the battery pack feels hot, let it cool for 30 minutes before charging. • Replace any damaged parts with the proper Bullard replacement part to maintain the NIOSH approval.
  • Page 4: Checking Air Flow / Air-Purifying Elements

    Remain calm and LEAVE the hazardous area immediately. DO NOT use a blower that fails the flow test (air flow indicator sold separately). Use ONLY Bullard filter/cartridges which comply with and have the NIOSH approval label and which are appropriate for the contaminant.
  • Page 5: Donning The Blower / Low Battery Alarm

    EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (Incorporating the Bullard FAMB® Series Half Face Mask) NOTE • Place the plastic headband straps on your head so the top plastic strap rests across the top your head and the bottom plastic strap rests above Plastic insert may be removed for cleaning as shown in Figure 13-14 .
  • Page 6: Low Battery Alarm / Doffing The Blower

    The Low Flow Alarm will sound a continuous 77 dba electronic beep indicating that the flow to the mask has dropped to the design specification of 115 lpm = 4.0 CFM (Note: The NIOSH minimum required flow is 115 lpm=4 CFM). www.bullard.com...
  • Page 7: Troubleshooting

    EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (Incorporating the Bullard FAMB® Series Half Face Mask) Troubleshooting The following guide will assist you in troubleshooting to locate possible issues with your respirator: Circumstance Possible Cause(s) Solution Low Battery Alarm is sounding...
  • Page 9: Inspection / Cleaning / Storage

    EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (Incorporating the Bullard FAMB® Series Half Face Mask) Inspection and Cleaning Mask Immerse the facepiece in warm water (about 120º F) with mild � WARNING detergent or a germicidal disinfecting detergent. The respirator Avoid contaminant entry into the breathing tube, as this will body and parts may be scrubbed gently with a cloth or soft brush.
  • Page 10: Fit Testing / Warranty / Return Authorization

    According to OSHA’s Respiratory Standard, 29 CFR 1910.134, all tight-fitting facepieces must not be fit tested, regardless of the mode of operation. This includes all respirator models in the EVA Series when use with the FAMB Series mask. User must pass either a qualitative or quantitative fit test, and fit testing must be performed in the negative pressure mode.
  • Page 11: Famb Diagram

    EVA Series Powered Air-Purifying Respirator Blower Assembly User Manual (Incorporating the Bullard FAMB® Series Half Face Mask) Bullard FAMB Half Mask Cat. No. Description 1. FAM2L, FAM2M, FAMS Half Mask, Large/Medium/Small 2. FAM2EVF10 Valve Flapper, Exhalation (pack of 10) 3. FAM2EVS2 Seat, Ehalation Valve (pack of 2) 4.
  • Page 12: Ordering Information

    53424 Remagen • Germany 701, Sims Drive, #04-03 ©2013 Bullard. All rights reserved. Toll-free within USA: 877-BULLARD (285-5273) Tel: +49-2642 999980 Singapore 387383 EVA and FAMB are trademarks of Bullard. Tel: +1-859-234-6616 Fax: +49-2642 9999829 Tel: +65-6745-0556 Fax: +1-859-234-8987 Fax: +65-6745-5176 6081509086C (1113) w w w .

This manual is also suitable for:

EvafamlEvafammEvafamsEva1Eva5Eva6 ... Show all

Table of Contents