Chapter 2. Installation

This chapter presents step-by-step installation instructions for
this eight-port Fiber-optic Fast Ethernet Switch.

Selecting a Site for the Switch

As with any electronic device, you should place the Switch where
it will not be subjected to extreme temperatures, humidity, or
electromagnetic interference. Specifically, the site you select
should meet the following requirements:
The room temperature should be between 32 and 104
degrees Fahrenheit (0 to 40 degrees Celsius).
The relative humidity should be less than 90 percent,
non-condensing.
Surrounding electrical devices should not exceed the
electromagnetic field (RFC) standards for IEC 801-3,
Level 2 (3V/M) field strength.
Make sure that the switch receives adequate ventilation.
Do not block the ventilation holes on the side of the switch
or the fan exhaust port on the rear of the switch.
The power outlet should be within 1.8meter (6 feet) of the
switch.
Detailed specifications may be found on page 22 and 23.
FNSW-8086 / 8088F User's Guide
13