CONNECTING THE GRILL TO AC POWER
Turn the Grill Off
Set the cook control switch to the off position.
Plug the Grill In
Connect the grill to AC power. The control displays its model number and software version.
If you see "ErP"
If the cook control switch is in the smoke position or any temperature setting when the grill is plugged in, the control
will display "ErP" indicating an inadvertent start error. The standard ignition sequence is halted. This feature prevents
an inadvertent start. For example, if the grill is stored in the garage, the grill will not ignite if plugged in inadvertently.
To clear the error, set the cook control switch to off .
Cook Control
To ignite the grill, set the cook control switch to the smoke position or any temperature setting.
Ignition Sequence
- The draft fan turns on.
- The igniter turns on.
- The fuel feed auger turns on and delivers fuel continuously for two minutes.
- The grill temperature is displayed along with three fl ashing dots signifying that the igniter is on.
The igniter will turn off when one of the following three conditions is met:
- The igniter has been on for four minutes and the grill temperature has increased by 30 degrees.
- The igniter has been on for four minutes and the grill temperature is greater than 150 degrees.
- The igniter has been on for fi ve minutes.
Once the igniter turns off , if the cook control switch is set to the Smoke position, the grill operates in smoke mode.
If the cook control switch is set to a temperature setting, the grill operates in cook mode. The fl ashing dots are turned off .
Cook Control
Set the cook control switch to the desired temperature. The control displays the grill's current temperature.
Cook sequence once the ignition sequence is complete and the igniter turns off , the auger feeds fuel into the fi re pot
to maintain the set temperature.
IGNITING THE GRILL
COOKING