TROUBLEShOOTING SUGGESTIONS

SYMPTOM
Water won't heat (be sure TANK
HEAT switch is ON)
Coffee level low (pour-over)
Coffee level too high or low
(automatic)
Brew chamber overflows
Sprays water from brew head
No brew (automatic)
No flow from hot water faucet
Poor coffee quality
POSSIBLE CAUSE
Brewer unplugged or circuit breaker
tripped
Thermostat set too low
Hi-Limit thermostat tripped
Damaged internal component or wiring
Pour-over - no water or too little water
added at startup
Not enough water poured in
Too much coffee grounds
Timer out of adjustment
Too many filter papers or wrong filter
paper
Brew chamber dispense hole plugged
Too much coffee or too fine a grind
Spray gasket improperly installed
Spray disk plugged
Water supply OFF
Solenoid strainer plugged
Water filter (if used) plugged
Bad BREW switch
Damaged internal component or wiring
Faucet valve turned OFF
Faucet plugged
Water not hot enough or too hot
Spray disk not installed
Keep brewer, airpots and servers clean. Install a taste and odor filter in water
supply, and replace cartridges regularly. Use a quality coffee with a consistent
roast. Use proper grind and amount of coffee per brew.
10
SUGGESTED REMEDY
Check power supply cord Check /
reset circuit breaker
Set for desired temperature
Allow to cool, Reset hi-limit (8786,
8788)
Examine wiring & connectors,
thermostat and heating element,
Repair/replace as needed
Be sure to add sufficient water
Increase water amount
Adjust amount of grounds
Adjust timer
Use one (1) genuine Bloomfield filter
per brew
Thoroughly clean brew chamber
Adjust coffee amount and grind
Check/reinstall gasket on INSIDE of
brew head
Clean spray disk
Turn water supply ON
Clean strainer
Replace filter element
Replace switch
Examine wiring & connectors, brew
switch and solenoid Repair/replace as
needed
Turn faucet valve ON
Disassemble faucet, clean
Adjust water temp 195-205ºF
Properly installed spray disk and
gasket