Cleaning And Servicing The Iu0U Automatic Charger; Rectifying Faults - Waeco PerfectCharge IU152A Installation And Operating Manual

Iu0u automatic charger
Table of Contents

Advertisement

PerfectCharge
10.5
Functional check
The charging of the batteries can be monitored by means of an LED on the
front of the device:
LED
I Phase
U0 Phase
U Phase
11
Cleaning and servicing the IU0U auto-
matic charger
Caution
a
Do not use any sharp or hard objects for cleaning since they may
damage the device.
➤ Clean the IU0U automatic charger with a damp cloth from time to time.
12

Rectifying faults

Caution
a
This chapter is intended for technicians who are familiar with the
guidelines and safety precautions to be applied.
Note
I
If you have questions concerning details of the battery specifica-
tions please contact the battery manufacturer.
The voltage of the battery does not rise after the IU0U automatic
charger has been connected and put into operation.
➤ Use a suitable multimeter to check whether the voltage of the battery ter-
minals rises during charging.
➤ Check whether the terminals are connected properly to the battery termi-
nals.
➤ Clean the battery terminals as necessary.

Cleaning and servicing the IU0U automatic charger

Battery charge status
Between 10% and 50%
Between 50% and 90%
Above 90%
53