9. To install the module, reverse step 8. When
installing the module into the cabinet, the
cord must be fed through the opening in the
cabinet back panel. Be careful that the seals
on the side of the module go inside the
module slides.
To descale the humidity generator:
To clean the humidity generator, use a
commercially available descaling solution
that is compatible with the stainless steel
humidity generator and the aluminum
cabinet interior. Pour the descaling solution
into the water bottle, using the
manufacturer's recommended dilution. With
the bottle connected to the module, run the
humidity generator at the maximum humidity
III. FOOD HOLDING GUIDELINES
A. FL2000 Recommended Food Holding Guidelines
Food Product
Baked Fish
Baked Potatoes
Biscuit
Broccoli
Chicken Nuggets
Corn on the Cob
Croissants
Egg Patties
French Fries**
Fried Chicken
Fried Fish
Hamburgers
Lasagna
Mashed Potatoes
Mixed Veggies
Pancakes
Pasta
Peas
Pizza
Roast Beef
Roast Pork
Scalloped Potatoes
Strip Steak
Turkey
Waffles
Whole Chicken
*Temperatures are guidelines only, based on opening cabinet doors every 15 minutes.
**Lightly salted for best quality.
Developed by Penn State University School of Hotel, Restaurant, and Recreation Management
Covered/Uncovered
Uncovered
Uncovered
Uncovered
Covered
Uncovered
Covered
Uncovered
Covered
Uncovered
Uncovered
Uncovered
Covered
Covered
Covered
Covered
Covered
Covered
Covered
Uncovered
Uncovered
Uncovered
Covered
Uncovered
Uncovered
Covered
Uncovered
5
setting for the manufacturer's recommended
time. Then, shut off the module, remove the
water bottle and allow all the solution to drain
out of the module quick disconnect valve.
Empty the water bottle, and refill with clean
water and a cup of baking soda and reinstall
the bottle. Run the cabinet for another 30
minutes with the humidity generator at the
maximum humidity setting. Again, shut off
the module, remove the water bottle,
allowing all the water to drain out of the front
panel quick disconnect valve. Empty the
water bottle and rinse; replace the bottle into
the cabinet and refill with clean, cold water.
The cabinet is now ready to use.
Temperature Setting °F*
175
180
180
170-175
175
170-175
175
180
185
180-185
180
180
185
175
170-175
175
180
170-175
175-180
170-180
170-180
175
160-170
170-180
175
170-180
Moisture Setting
Med/High
Off
Medium
High
Off
High
Medium
High
Off
Off
Off
Medium
High
High
High
Medium
High
High
High
Medium
Medium
High
Medium
Medium
Medium
Medium
Need help?