Instructions for the Installer

Engineers technical data

Overall dimensions
Cut out dimensions
Supply connections
Gas:
Electric:
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE m
NOZZLE REFERENCE
NOMINAL THERMAL
POWER kW
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
BURNER
RAPID
(large)
POSITION
MAX
2.9
/h
0.276
0.062
3
119
Adjust.
1/100 mm
2.7
g/h
195
86
1/100 mm
Ignition HT Spark
Semi-rapid Burner
Rapid Burner
Auxiliary Burner
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.65
1.9
0.45
1.0
0.181
0.043
0.095
96
Adjust.
70
0.65
1.9
0.45
1.0
46.8
137
32.4
72
40
71
32
50
APPLIANCE CLASS:
APPLIANCE CATEGORY:
APPLIANCE GAS SUPPLY:
(small)
MIN
0.33
0.031
Adjust.
0.33
23.8
28
7