Instructions For The Installer; Important Safety Requirements - Electrolux EHG 65 Instruction Booklet

Hide thumbs Also See for EHG 65:
Table of Contents

Advertisement

Instructions for the Installer

Engineers technical data
OVERALL DIMENSIONS
Width:
580 mm.
Depth:
500 mm.
CUT OUT DIMENSIONS
Width:
550 mm.
Depth:
470 mm.
TYPE
TYPE
OF BURNER
OF GAS
Triple Crown (wok)
NATURAL
Semi-rapid (medium)
GAS
Auxiliary (small)
Triple Crown (wok)
U-LPG
Semi-rapid (medium)
Auxiliary (small)

Important safety requirements

Location
Choose a location free of draughts and open doors and
clear of combustible materials or other fire hazards such
as curtains, etc. The location should ensure convenience
of operation and service. Any adjacent wall surface
situated within 200mm from the edge of any hob burner
and above the height of the hob must be a suitable non-
combustible material for a height of 150 mm for the entire
depth and width of the cooker.
Any combustible material above the hotplate must be at
least 650 mm above the top of the hob and no
construction shall be within 450 mm above the top of the
burner.
A minimum distance of 100 mm. must be left between
the side edges of the hob and any adjacent cabinets or
walls.
6
All manuals and user guides at all-guides.com
NOZZLE
NOMINAL
MARKS
GAS
1/100 mm CONSUMPTION
MJ/h
1.57
13.00
1.11
6.80
0.89
3.80
0.97
13.00
0.71
6.30
0.55
3.80
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply
APPLIANCE GAS SUPPLY:
Natural gas 1.0 kPa - Universal LPG 2.75 kPa
Burner
NOMINAL
PRESSURE
kPa
Auxiliary
Semi-rapid
Triple crown
1.00
Aeration adjustment none
2.75
WITHOUT A COOKER HOOD ABOVE
700 mm
650 mm
Dia. Tap By-pass
1/100 mm
28
35
42
FITTING THE GAS HOB
400 mm
400 mm
FO 0812
FITTING THE GAS HOB
WITH A COOKER HOOD ABOVE
400 mm
400 mm
FO 0813

Advertisement

Table of Contents
loading

Table of Contents