Engineers Technical Data - Zanussi ZGP 982 Instruction Booklet

Gas hob
Hide thumbs Also See for ZGP 982:
Table of Contents

Advertisement

Instructions for the Installer

Engineers technical data

OVERALL DIMENSIONS
SUPPLY CONNECTIONS
Gas:
Electric:
Characteristics
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
NOMINAL THERMAL
POWER
NOMINAL FLOW
RATE
NOZZLE REFERENCE
Burner
Dia. Tap By-pass
1/100 mm
BURNER
RAPID
(large)
POSITION
MAX
kW
3.0
m
/h
0.286
3
119
Adjust.
1/100 mm
kW
2.8
g/h
202
86
1/100 mm
Rear Left Burner (semi-rapid)
Front Left Burner (rapid)
Rear Right Burner (semi-rapid)
Front Right Burner (auxiliary)
Central Burner (Ultra-rapid Double crown)
SEMI-RAPID
AUXILIARY
(medium)
MIN
MAX
MIN
MAX
0.65
2.0
0.45
1.0
0.062
0.190
0.043
0.095
96
Adjust.
70
0.65
2.0
0.45
1.0
47
144
32
72
40
71
32
50
APPLIANCE CLASS:
APPLIANCE CATEGORY:
APPLIANCE GAS SUPPLY:
ULTRA-RAPID
(small)
(double crown)
MIN
MAX
MIN
0.33
3.5
1.2
0.031
0.333
0.114
Adjust.
136
Adjust.
0.33
3.5
1.2
24
252
86
28
93
56
9