Air Circulation - Electrolux Refrigerator Service Manual

Total no frost fifty sliding door
Hide thumbs Also See for Refrigerator:
Table of Contents

Advertisement

Unlike in the PARTIAL NO FROST refrigerator, in the TOTAL type the cooler and the freezer communicate each
other, therefore the battery evaporator cools both compartments.
The cold produced by the battery evaporator in the freezer compartment is distributed by the F fan placed
behind the cold module.
Cooler compartment air flow: the cold air is pushed by the fan into the foamed duct and exits from the air flow
regulator (damper) E located in the rear part of the diffuser-lamp holder. The air returns in the freezer
compartment by means of some foamed ducts entering the air vent grids G.
Freezer compartment air flow: the cold air is pushed into the compartment through the air screen and returns
into the cold module through the front air vent grid.
In case of opening of the freezer or cooler door, the fan stops.
To simulate the door closet use a magnet and put it next to the reed element placed on the
intermediate crosspiece or to the reed element placed on the electronic board.
TOTAL NO FROST FIFTY SLIDING DOOR

2. AIR CIRCULATION

G
E
F
8/39