Operation; Normal - Electrolux Refrigerator Service Manual

Total no frost fifty sliding door
Hide thumbs Also See for Refrigerator:
Table of Contents

Advertisement

Warning: unplug the appliance before operating.
In case of first switching on with a freezer compartment temperature higher then 10 °C, the appliance operates
with a test cycle (for the factory) for a maximum time of about 1,5 hours. In this period do not check the correct
functioning of the appliance, since the loads are activated only for internal check (compressor, fan, defrosting
heater, damper).
When the appliance is (OFF) then:
the compressor is off
the fan is off
the is display off
Pushing the ON/OFF button, the LCD display switches on with the following displaying:
sign +
red display background
freezer compartment temperature alarm (buzzer active)
Push the function activation button to deactivate the buzzer.
Regulate the compartment knobs so as to set the following temperatures:
about +5 °C in the cooler
about -18 °C in the freezer
In NO FROST refrigerators, the humidity inside the freezer compartment accumulates on the evaporator battery
thanks to the air circulation, thus preventing the formation of frost on food.
During normal operation time the electronic board powers the compressor and the fan circuit. The fan and
compressor operation is independent (the fan is on only when the compressor is on).
The fan is deactivated with a 2 minute delay compared to the compressor.
The operation time which corresponds to the interval between the following defrosting lasts about 14 hours with
normal opening of the door (it can last up to 72 hours if the doors are never opened!).
TOTAL NO FROST FIFTY SLIDING DOOR

6. OPERATION

6.1. Normal

25/39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zi918/9ffaErf 2620

Table of Contents