Troubleshooting; Excessive Ice Formation On The Battery; Failed Defrosting - Electrolux Refrigerator Service Manual

Total no frost fifty sliding door
Hide thumbs Also See for Refrigerator:
Table of Contents

Advertisement

10.1. Excessive ice formation on the battery :

If the rubber valve remains open, the humid air outside the freezer compartment is ducted inside and it
accumulates too much ice on the battery. The valve remains open if there are foreign bodies or if it looses
elasticity; therefore in the first case the foreign bodies must be removed, while in the latter the rubber valve must
be replaced.

10.2. Failed defrosting:

In case of failed defrosting, the possible causes are:
Sequence
POSSIBLE
no.
CAUSES
1
The
heater
interrupted
2
One
switches
thermal protectors
are open
TOTAL NO FROST FIFTY SLIDING DOOR

10. TROUBLESHOOTING

Unplug the appliance before operating.
HOW TO CONTROL
defrosting
Unplug the appliance, remove the
is
connector of the heater and verify with
the tester the correct resistance value
to the connector clamps.
or
both
Frost the battery, then detach the
of
the
power plug of the appliance, remove
the connector of the thermal switches
and verify with the tester the correct
resistance value to the connector
clamps.
WARNING !
SOLUTION
If the resistance value does not
correspond to the technical data,
replace the heater.
If the resistance value does not
correspond to 0 (zero Ohm) replace
the thermal switches assembly.
36/39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zi918/9ffaErf 2620

Table of Contents