Chapter 5
When downloading a configuration file,
NOTE:
make sure that it is a valid configuration file. If
you have edited the file, ensure that only valid
entries have been configured.
Admin > Reboot
Admin > Reboot
The Reboot screen resets the device. The device
configuration is automatically saved before the device is
rebooted.
Admin > Factory Defaults
The Factory Reset screen allows network managers to
reset the device to the factory defaults shipped with the
switch. Restoring factory defaults results in erasing the
configuration file.
Admin > Factory Defaults
8-Port 10/100 Ethernet Switch with Webview
Advanced Configuration
Restoring the factory defaults will
NOTE:
erase all configuration settings that you have
made. You can save a backup of your current
configuration settings from the Admin > Save
Configuration screen.
Admin > Server Logs
The Server Logs screen contains information for viewing
and configuring the Remote Log Servers. New log servers
can be defined, and the log severity sent to each server.
Admin > Server Logs
Specifies the server to which logs can be sent.
Server
Defines the UDP port to which the
UDP Port (1-65535)
server logs are sent. The possible range is 1 to 65535. The
default value is 514.
Defines a user-defined application from which
Facility
system logs are sent to the remote server. Only one facility
can be assigned to a single server. If a second facility level
is assigned, the first facility is overridden. All applications
defined for a device utilize the same facility on a server.
The field default is Local 7. The possible field values are
Local 0 - Local 7.
Provides a user-defined server description.
Description
Indicates the minimum severity from
Minimum Severity
which logs are sent to the server. For example, if Notice
is selected, all logs from a Notice severity and higher are
sent to the remote server.
The Add to List button adds the Server Log configuration
to the Server Log Table at the bottom of the screen.
56