By rotating the timer shaft clockwise, with the help of a screwdriver, two clicks that indicate the closure of the
contacts are heard. As it is shown in the picture (the position of the clicks is merely indicative), between the 1
nd
click and the 2
click the run is shorter, between the 2
Warning:
In order to test the appliance during "normal" operation, it is necessary to rotate the timer cam till the 2
-
so as to close contact 3-2;
-
In order to test the appliance during "defrosting" operation, it is necessary to rotate the timer cam till the 1
click so as to close contact 3-4.
4 DOOR REFRIGERATOR WITH R600a
nd
st
click and the 1
click the run is longer:
st
nd
click
st
21/22