Mitsubishi Electric PLFY-P·NAMU-E Operation Manual page 18

Air-conditioners for building application indoor unit
Table of Contents

Advertisement

Available languages

Available languages

11. Specifications
I PKFY Series
Model
Power source
Capacity
Dimension
Net weight
Fan Airflow range
(Low-Middle2-Middle1-High) WET
Noise level
(Low-Middle2-Middle1-High)
Model
Power source
Capacity
Dimension
Net weight
Fan Airflow range
(Low-High)
Noise level
(Low-High)
I PMFY Series
Model
Power source
Capacity
Dimension (Grille)
Net weight (Grille)
Fan Airflow range
(Low-Middle2-Middle1-High) WET
Noise level
(Low-Middle2-Middle1-High)
Range of application
The range of working temperatures for both the indoor and outdoor units of the series Y is as below.
Caution:
The use of your air conditioner outside the range of working temperature and humidity can result in serious failure.
Mode
Indoor unit
Cooling
59 °F - 75 °FWB
Heating
59 °F - 81 °FDB
Note: As an applicable humidity standard for both indoors and outdoors, we recommend use within a range of 30 - 80% relative humidity.
Warning:
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since there may be a refrigerant
leak. Be sure to ask the service representative whether there is refrigerant leakage or not when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas leaks indoors, and comes
into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated.
18
PKFY-P06NAMU-E PKFY-P08NAMU-E PKFY-P12NGMU-E PKFY-P15NGMU-E
Cooling <BTU/h>
6,000
Heating <BTU/h>
6,700
H
<inch>
W
<inch>
D
<inch>
<Ibs>
DRY
<CFM>
170-180-200-210
<CFM>
160-170-180-190
<dB(A)>
32-33-35-36
PKFY-P18NFMU-E PKFY-P24NFMU-E PKFY-P30NFMU-E
Cooling <BTU/h>
18,000
Heating <BTU/h>
20,000
H
<inch>
W
<inch>
D
<inch>
<Ibs>
DRY
<CFM>
490-640
WET
<CFM>
440-570
<dB(A)>
PMFY-P06NBMU-E PMFY-P08NBMU-E PMFY-P12NBMU-E PMFY-P15NBMU-E
Cooling <BTU/h>
6,000
Heating <BTU/h>
6,700
H
<inch>
W
<inch>
D
<inch>
<Ibs>
DRY
<CFM>
230-250-280-300
<CFM>
200-220-250-270
<dB(A)>
27-30-33-35
Outdoor unit
PUHY
23 °F - 110 °FDB
5 °F - 60 °FWB
Single 208/230 V 60 Hz
8,000
12,000
9,000
13,500
11-5/8
32-1/8
6-1/4
19
280-340-370-410
250-300-330-370
32-36-40-42
Single 208/230 V 60 Hz
24,000
30,000
27,000
34,000
13-3/8
55-1/8
66-1/8
9-1/4
53
62
780-990
700-890
39-45
46-49
Single 208/230 V 60 Hz
8,000
12,000
9,000
13,500
9-1/16(1-3/16)
33-5/8(39-3/8)
1/-9/16(18-1/2)
31(7)
250-280-300-320
220-250-270-290
32-34-36-37
15,000
17,000
13-3/8
39
9-1/4
35
15,000
17,000
270-300-340-370
240-270-310-340
33-35-37-39