● OPERATING INSTRUCTIONS ●
I
-SEE OPERATION

i-see control mode

In the i-see control mode, the room temperature is controlled based on the
sensible temperature.
1
Press
during COOL, DRY, HEAT and AUTO mode
to activate the i-see control mode.
• Press gently using a thin instrument.
lights. (Operation display section)
• The default setting is "active".
2
Press
again to activate ABSENCE DETECTION.
lights. (Operation display section)
3
Press
again to release the i-see control mode.
Note:
Any person at the following places cannot be detected:
• Along the wall on which the air conditioner is installed
• Directly under the air conditioner
• Where any obstacle, such as furniture, is between the person and the air
conditioner
A person may not be detected in the following situations:
• Room temperature is high.
• A person wears heavy clothes and his/her skin is not exposed.
• A heating element of which temperature changes significantly is present.
• Some heat sources, such as a small child or pet, may not be sensed.
• A heat source and the air conditioner are more than 20 ft (6 m) apart.
• A heat source does not move for a long time.
En-5

ABSENCE DETECTION

This function automatically changes the operation to energy-saving operation
when nobody is in the room.
1
To activate this function, press
on the operation display of the remote controller.
2
Press
again to release ABSENCE DETECTION.

INDIRECT/DIRECT mode

The INDIRECT/DIRECT mode offers fi nely-tuned operation by locating where
an occupant is in the room.
1
Press
during COOL, DRY, HEAT or AUTO
mode to activate the INDIRECT/DIRECT mode. This
mode is only available when the i-see control mode is
effective.
2
Each press of
changes INDIRECT/DIRECT in
the following order:
(INDIRECT)
(DIRECT)
(INDIRECT) : An occupant will be less exposed to
direct airfl ow.
(DIRECT)
: Mainly the vicinity of an occupant will
be air-conditioned.
• Horizontal and vertical airflow directions will be automatically select-
ed.
• When more than a couple of people are in a room, the INDIRECT/DI-
RECT mode may work less effectively.
• If you still feel uncomfortable with the air direction determined by the
INDIRECT mode, adjust the air direction manually.
3
Canceling the i-see control mode automatically cancels
the INDIRECT/DIRECT mode.
• The INDIRECT/DIRECT mode is also cancelled when the VANE or
WIDE VANE buttons is pressed.
Note:
• Do not touch the i-see sensor. This may cause malfunction of the i-see sen-
sor.
• The intermittent operating sound is a normal sound produced when the i-see
sensor is moving from side to side.
until