Advertisement

Quick Links

Speed Dome
EPTZ Series

USER MANUAL

Copyright © EverFocus Electronics Corp,
Release Date: Aug, 2013

Advertisement

Table of Contents
loading

Summary of Contents for EverFocus EPTZ Series

  • Page 1: User Manual

    Speed Dome EPTZ Series USER MANUAL Copyright © EverFocus Electronics Corp, Release Date: Aug, 2013...
  • Page 2: Table Of Contents

    Analogue IR speed dome series Table of Contents EPTZ860 Overview ..................5 1.1. Introduction ....................5 1.2. Specifications ..................... 6 1.3. Feature ......................8 1.4. Alarm ......................8 1.5. EPTZ860 Quick Operation Guide (Work with EKB500) ......9 1.6. Packing List ....................10 1.7.
  • Page 3 Analogue IR speed dome series Default value is 1185 ..................21 b. CHECK ID ( 0000~9999) ................21 Default value is 0 ....................21 c. TARGET ID ....................21 d. BAUD TATE ....................21 1.12. Dome ......................21 1.11.0 PRESET ....................22 1.11.1 SCAN ....................
  • Page 4 Analogue IR speed dome series 1.17. Reset ....................... 29 1.18. Exit ........................29...
  • Page 5: Eptz860 Overview

    Analogue IR speed dome series EPTZ860 Overview 1.1. Introduction EPTZ860 is outdoor type, using high sensitivity and high resolution CCD to display high quality image. The design of ICR (IR cut filter removable) can provide real color even under strong sunlight in day time. Under slight light in night time, a clear image can still be displayed.
  • Page 6: Specifications

    Analogue IR speed dome series are controlled by keyboard EKB500. Built-in fan to enhance heat dissipation at high temperature and circulate heat to keep system operation at low temperature. Built-in 4 alarm inputs and 2 alarm outputs. All of the features make the intelligent high-speed dome camera works for a wide range and demanding application such as banks, airports, stations, casinos, streets of cities, intelligent buildings, etc.
  • Page 7 Analogue IR speed dome series Tilt Rotation Range 94°Pendulum motion Auto Speed Control control speed auto-adjusted according to zoom length changing Auto Pan Speed 300°/s Dwell Time at Preset Position 0.5-10S,4 groups Tour 4 groups Tour Point Per Group 16Preset positions Pattern 4PCS Communication...
  • Page 8: Feature

    Analogue IR speed dome series 1.3. Feature Profile of EPTZ860 1.4. Alarm Function direction list: Pin # Function ALMIN1 (Alarm Input 1) ALMIN2 (Alarm Input 2) ALMIN3 (Alarm Input 3) ALMIN4 (Alarm Input 4) GND (Alarm input Common) ALARM NC OUT (Alarm Output Normal Close ) ALARM OUT COM (Alarm Output Common ) ALARM NO OUT (Alarm Output Normal Open)
  • Page 9: Eptz860 Quick Operation Guide (Work With Ekb500)

    Analogue IR speed dome series Label as below : 1.5. EPTZ860 Quick Operation Guide (Work with EKB500) EPTZ860 and EKB500 (Keyboard) can work together by using factory default setting. You just need to connect cables by the following steps: 1. Connect the RS-485 cable to EPTZ860 and a keyboard (EKB500). 2.
  • Page 10: Packing List

    Analogue IR speed dome series 1. Shift the Joystick up/down or right/left to view from camera. 2. Turn the top of the Joystick to zoom in/out. 3. Press Zoom In/Out, Focus F. /N. and IRIS +/- function keys to operate the EPTZ860. 1.6.
  • Page 11: Initial Setup

    Analogue IR speed dome series Video Cable A BNC cable is used for connecting an EPTZ860 to a DVR or a monitor. An amplifier may be needed if the video cable is too long. RS485 Cable Yellow wire represents RS485+, orange wire represents RS485-. Connect RS485 to EKB500 and you will be able to control the speed dome by a keyboard.
  • Page 12 Analogue IR speed dome series Note: The factory default address is 1. Notice: Please make sure the power is off before setting, and restart the EPTZ860 to enable a new value after changing. Note: You will see the label of Protocol & Baud Rate as well as RS-485 ID address show on the speed dome.
  • Page 13 Analogue IR speed dome series Switch Address Switch Switch Switch Address Address Address Switch Switch Switch Switch Address Address Address Address Switch Switch Switch Switch Switch Address Address Address Address Address...
  • Page 14 Analogue IR speed dome series Switch Address Switch Switch Switch Address Address Address Switch Switch Switch Switch Address Address Address Address Switch Switch Switch Switch Switch Address Address Address Address Address...
  • Page 15: Communication Protocol Setting

    Analogue IR speed dome series Communication Protocol Setting The 1 and 3 bits are used to set communication protocol. The factory default protocol is EVF. Notice: Please make sure the power is off before setting, and restart the EPTZ860 to enable a new value after changing.
  • Page 16: Bracket And Speed Dome Installation

    Analogue IR speed dome series 1.9. Bracket and Speed Dome Installation Installation Requirements 1. Installation should be handled by a qualified service agent and should comply with all local regulations. Service personnel should expect potential problems such as surface strength, surface material, falling objects, outer breaches, building vibration or other similar conditions.
  • Page 17: Eptz860 Speed Dome Camera Wall Mount Simple Installation

    Analogue IR speed dome series EPTZ860 Speed Dome Camera Wall Mount Simple Installation 1. Screw the top housing to bracket by using a hexagon wrench. Put the waterproof silicon pad on top of the bracket base for waterproof purpose. Waterproof silicon pad Bracket base 3.
  • Page 18 Analogue IR speed dome series 4. Screw in 4 screws for mounting the bracket base. 5. Screw in 4 long screws to fix the bracket to bracket base. Note : The camera module on the mechanical part is very sensitive. Please be careful when installing this part.
  • Page 19: Eptz860 Camera Setup Menu

    Analogue IR speed dome series Note: When turning on the power, EPTZ860 will enter self-inspection mode, and carry out a self-testing program. After finishing self-inspection, you can start to operate the EPTZ860. EPTZ860 Camera Setup Menu In this section, setup and operation guide of EPTZ860 will be introduced. There are 9 items of the setting menu.
  • Page 20: System

    Analogue IR speed dome series <SYSTEM> <DOME> <CAMERA> <IR> <DISPLAY> <TIME> <LANGUAGE> <RESET> EXIT (diagram 3.1) 1.11. System In main menu, turn joystick Up / Down to select SYSTEM option. Turn joystick Left / Right to enter SYSTEM sub-menu (see diagram 3.2). <PROTOCOL >...
  • Page 21: Protocol> ( Pelco-D/P)

    Analogue IR speed dome series 1.10.0 <PROTOCOL> ( PELCO-D/P) 1.10.1 <COMM> ( 2400.N.8.1) 1.10.2 <DOME ID> ( 1 ) 1.10.3 <MODULE> (WX) 1.10.4 <VERSION> ( V3.614P) 1.10.5 <COM SET> a. DEVICE ID ( 0000~9999) Default value is 1185 b. CHECK ID ( 0000~9999) Default value is 0 c.
  • Page 22: Preset

    Analogue IR speed dome series 1.11.0 PRESET PRESET NO.001 ( The default is PRESET NO.001) CALL PRESET SET PRESET Press Enter key of keyboard to enter PRESET sub-menu. <PRESET> <SCAN> PRESET NO.001 <GUARD TOURS> CALL PRESET <PATTERN> SET PRESET <PRIVACY ZONE> EXIT <OTHER>...
  • Page 23: Pattern

    Analogue IR speed dome series 1.11.3 PATTERN PATTERN NO.1 CALL PATTERN PATTERN Press Enter key of keyboard to enter PATTERN sub-menu. <PRESET> <SCAN> PATTERN NO.1 PRESET <GUARD TOURS> CALL PATTERN PRESET NO.001 <PATTERN> <PATTERN> CALL PRESET <PRIVACY ZONE> EXIT SET PRESET <OTHER>...
  • Page 24 Analogue IR speed dome series Press Enter key of keyboard to enter PARK MODE sub-menu. NONE PARK MODE PATTERN1 PARK TIME TOUR1 POWER ON ACT 360SCAN RATIO SPEED AB SCAN AUTO FLIP PRESET1~PRESET8 EXIT EXIT (diagram 3.9) PARK TIME (1 ~ 60) The default is 5 POWER ON ACT MEMORY (The default is MEMORY)/ PATTERN 1/ TOUR 1/ 360SCAN/ AB SCAN/ PRESET 1~PRESET 8...
  • Page 25: Alarm

    Analogue IR speed dome series PARK MODE The default is ON PARK TIME OFF The default is ON POWER ON ACT EXIT RATIO SPEED AUTO FLIP EXIT (diagram 4.1) AUTO FLIP ( ON/ OFF) The default is ON Press Enter key of keyboard to enter AUTO FLIP sub-menu. The default is ON PARK MODE OFF The default is ON...
  • Page 26: Camera

    Analogue IR speed dome series ALARM IN ( ON/ OFF) ALARM IN ( NC/ NO) C PATROL TIME ( 05S~10S) ALARM 1 ( PR BIG/ PRESET 1~ PRESET 16) ALARM 2 ( PR LOW/ PRESET 1 ~ PRESET 16) ALARM 3 Turn joystick up ( PRESET 21/ PRESET43/ PRESET 65/ PRESET 87/ PRESET 109/ PRESET 121/ PRESET 43/ PRESET 65) Turn joystick down ( PRESET 1~ PRESET 16)
  • Page 27: Ir Mode

    Analogue IR speed dome series 1.13.0 IR MODE AUTO LARGE LIGHT C SMALL LIGHT d MANUAL e OFF Press Enter key of keyboard to enter IR MODE sub-menu. IR MODE AUTO OUTPUT POWER LARGE LIGHT TESTING TIME SMALL LIGHT STANDBY POWER MANUAL STANDBY TIME ILLUMINATION ON...
  • Page 28: Display

    Analogue IR speed dome series 1.15. Display In main menu, turn joystick Up or Down to select DISPLAY option. Press Enter key or turn joystick Left / Right to enter DISPLAY sub-menu (See diagram 4.6). <SYSTEM> DOME ID ON/OFF <DOME> ZOOM ON/OFF <CAMERA>...
  • Page 29 Analogue IR speed dome series <SYSTEM> ENGLISH <DOME> PORTUGUESE <CAMERA> FRENCH <IR> GERMAN <DISPLAY> ITALIAN <TIME> SPANISH <LANGUAGE> EXIT <RESET> EXIT (diagram 4.7) 1.17. Reset In main menu, turn joystick Up or Down to select RESET option. Press Enter key or turn joystick Left / Right to enter RESET sub-menu (See diagram 4.8).
  • Page 30 Analogue IR speed dome series EverFocus Electronics Corp. Europe Office: Head Office: Albert-Einstein-Strasse 1 12F, No.79 Sec. 1 Shin-Tai Wu Road, D-46446 Emmerich, Germany Hsi-Chih, Taipei, Taiwan TEL: +49(0)-2822-9394-0 TEL: +886-2-26982334 FAX: +49(0)-2822-9394-95 FAX: +886-2-26982380 www.everfocus.de www.everfocus.com.tw China Office: USA L.A. Office: Room B-05D-1, KESHI PLAZA, Shangdi 1801 Highland Ave.

This manual is also suitable for:

Eptz860

Table of Contents