16. Surround and Brass Trim Assembly Instructions (Three Piece Surround & Picture Frame)
Before attaching surround assembly, check operation of insert and installation of draft hood and chimney
liner.
To assemble surround attach panel (A), (B), (C), and (A1) if Picture Frame was purchased) with bolts
(10/24) and star lock nuts, if optional brass panel kit was purchased install at this time over the surround kit
and tighten the bolts to secure all panels.
All brass trims (D), (E), and (F) are installed with 5/16 x 6/32 self tapping screws, attach part (D), (E) and
(F) to outer edge of surround. Than place On/Off switch into slot (upper right corner) after trim has been
attached to surround. Route wires through 3/4" grommet hole, down right side of surround into right side
of insert. A hole is provided in blower intake box to route wires over to the valve, attach at TP and TP- TH.
(Refer to Wiring Diagram Section 19)
16