Kingsman MQZCV48NE Installation Instructions Manual

Vented gas fireplace heater
Hide thumbs Also See for MQZCV48NE:
Table of Contents

Advertisement

Model Numbers:
Certified to:
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.
-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
-WHAT TO DO IF YOU SMELL GAS
 Do not try to light any appliance.
 Do not touch any electrical switch; do not use any phone in your building.
 Leave the building immediately.
 Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
 If you cannot reach your gas supplier, call the fire department
-Installation and service must be performed by a qualified installer, service agency or the gas
supplier.
Installation Instructions
MQZCV48N, MQZCV48NE, MQZCV48NE2,
MQZCV48LP, MQZCV48LPE, MQZCV48LPE2,
ANSI Z21.88-2016 • CSA 2.33-2016, CSA 2.17-2016
VENTED GAS FIREPLACE HEATER
INSTALLER: Leave this manual with the
appliance.
CONSUMER: Retain this manual for
future reference.
For Propane Horizontal
installations the venting must
be an additional one foot
above the minimum vertical
rise off the flue before going
horizontal.
A Division of R-Co. Inc.
2340 Logan Ave.
Winnipeg, Manitoba Canada
R2R 2V3 Ph.: (204) 632-1962
Printed in Canada June 10, 2019
Part# 48ZCV-MAN16
BENTLEY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MQZCV48NE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kingsman MQZCV48NE

  • Page 1 Installation Instructions Model Numbers: MQZCV48N, MQZCV48NE, MQZCV48NE2, MQZCV48LP, MQZCV48LPE, MQZCV48LPE2, BENTLEY Certified to: ANSI Z21.88-2016 • CSA 2.33-2016, CSA 2.17-2016 VENTED GAS FIREPLACE HEATER This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    MQZCV48 Table of Contents INFORMATION Table of Contents……………………………………………………………..............Glass Safety / Termination Cap Safety- All Units……………………………………………………………………….. Warnings, Installations, and Operations…………………………………..............Pre-installation Questions and Answers…………………………………..............Operations and Maintenance Instructions......................Installations in Covered Outdoor Locations......................Mobile Home/Manufactured Housing Installation……………………............... MQZCV48 Framing Your Gas Fireplace………………………………………………………………………….... Nailing Tab Guide..............................
  • Page 3 IPI SECTION IPI Electronic Ignition System……………………………………………………………………………………………... Remote Control Operation…………………………………………………………………………………………………. IPI Electronic Ignition Parts List – Standard System……………………………………………………………………. Configuration 1: Basic Manual Hi / Lo and manual Off…………………………………………………………………. Configuration 2: Remote On / Off and manual Hi / Lo………………………………………………………………….. Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls………………………... Configuration 3: Remote ON/OFF, Variable HI/LO, and Fan…………………………………………………………..
  • Page 4: Glass Safety / Termination Cap Safety- All Units

    -Glass Safety- All Units IT IS THE RESPONSIBILITY OF THE HOME OWNER TO ENSURE THAT NO ONE TOUCHES A HOT APPLIANCE. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Any safety screen, guard, or barrier removed for servicing the appliance, must be replaced prior to operating the appliance.
  • Page 5: Warnings, Installations, And Operations

    Warnings, Installations and Operations - Installation Regulations This gas appliance must be installed by a qualified installer in accordance with local building codes, or in the absence of local codes, with the current CAN/CSA-B149.1 or .2 Installation Code (in Canada) or the current National Fuel Gas Code Z223.1- NFPA 54 when installed in the United States. This appliance, when installed, must be electrically connected and grounded in accordance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or with the National Electrical Code;...
  • Page 6 Installation Requirements for the Commonwealth of Massachusetts In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the requirements listed below.
  • Page 7: Pre-Installation Questions And Answers

    Pre-installation Questions and Answers About curing of the paint Your stove or fireplace has been painted with the highest quality silicone stove paint. This paint dries quickly in 15-20 minutes when first applied at the factory. However, due to the high temperature silicone components, the paint will cure when heat is applied to the appliance as it is first used.
  • Page 8: Installations In Covered Outdoor Locations

    Intertek safety certification will not apply to this installation method. This installation method must be deemed acceptable by the Authority Having Jurisdiction (AHJ) prior to the indoor gas fireplace being installed. Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected from direct water impingement.
  • Page 9: Mobile Home/Manufactured Housing Installation

    Mobile Home/Manufactured Housing Installation This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
  • Page 10: Mqzcv48 Framing Your Gas Fireplace

    MQZCV48 Framing Your Gas Fireplace This section is intended for qualified installers only. Before beginning, make note of where the gas and electrical accesses are located on the unit. This will streamline the construction process. Furthermore, familiarize yourself with the venting and clearance requirements (see Venting section) for this appliance.
  • Page 11: Nailing Tab Guide

    MQZCV48 Framing- Nailing Tab Guide [Qty]2 Nailing Tabs are located on each side of the front frame. These Nailing Tabs can be used in two ways: 1/2” Drywall Flush with Face of Fireplace – Framing Flush with Face of Fireplace -Fireplace to be covered with Non-Combustibles (e.g.
  • Page 12: Locating Your Appliance / Fireplace Dimensions

    MQZCV48 Locating Your Appliance LOCATION KEY: Flat on Wall Across the Corner As an Island As a Room Divider Flat on Wall Corner Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace. Island installation with a top vent is possible as long as the horizontal portion of the vent system does not exceed 20 feet (6.1 m).
  • Page 13: Framing Dimensions

    MQZCV48 Framing Dimensions Determine whether face of fireplace will be:  Flush with finished wall (e.g., for surround, cultured stone or other non combustible covering).  Flush with framing (to be covered with concrete board for a Flat Wall appearance). Optional Recess Refer to Nailing Tab Guide section also.
  • Page 14: Clearance To Combustibles

    MQZCV48 Clearance to Combustibles Clearance to Combustibles MQZCV48 Front 36” [92cm] Back (from Stand-offs) 0” [0cm] *Note: If appliance is installed directly on carpeting Side (from Stand-offs) 0” [0cm] or other combustible material Floor* 0” [0cm] other than wood flooring, a Minimum Ceiling Height (from bottom of fireplace) 66”...
  • Page 15: Facing Requirements

    MQZCV48 Facing Requirements Required Non-Combustible Areas Finishing Recommendations (Obtained from professional NOTE: ANY MATERIALS COVERING THE FACE OF THE construction contractors and finishers): FIREPLACE MUST BE NON-COMBUSTIBLE (i.e. brick, stone, tile, concrete board). FIREPLACE WITH SCREEN  Frame unit with metal studs (minimum 20 gauge).Wooden ONLY (AS SHIPPED) SHOWN HERE.
  • Page 16: Basic Finishing 1: With Screen Only (As Shipped)

    MQZCV48 Basic Finishing 1: With Screen Only (As Shipped) TO FINISH WALL WITH DRYWALL AND TILE TO FINISH WALL WITH DRYWALL AND OR BRICK: CONCRETE BOARD: Step 1: Frame fireplace with nailing tabs oriented as Step 1: Frame fireplace with nailing tabs oriented as shown.
  • Page 17: Zcv48Css Child Safety Screen Installation

    MQZCV48CSS Child Safety Screen Installation Contents of Kit: [1] Child Safety Screen- Ready to Install Assembly Instructions: Attach screen to fireplace as per instructions below. ⚠ WARNING: Wait until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screen.
  • Page 18: Basic Finishing 2: With Surround And Existing Screen

    ZCV47S1BL Basic Finishing 2: With Surround and Existing Screen PARTS LIST: [1] Surround and [8] DT screws. Surround attaches to safety screen supplied with fireplace. Install Screen with Surround attached as described in in Child Safety Screen Installation section. Step 1: Frame Fireplace with nailing tabs oriented as Step 2: Use Drywall to finish face of wall.
  • Page 19: Basic Finishing 3: Mqzcv48Dd Doors

    MQZCV48 Basic Finishing 3: MQZCV48DD Doors Step One: Frame Fireplace with nailing tabs oriented as Step Two: Use Drywall to finish face of wall. shown. NOTE: Wall will be flush with fireplace face. Drywall Fireplace Frame Nailing Tab Step 3: A stone, brick, or other non-combustible border IMPORTANT NOTE! When installing stone, brick, or other may be applied to the wall.
  • Page 20 ZCV48 Fireplace Opening Required Clearance ZCV48 Fireplace Opening Required Clearance...
  • Page 21: Mqzcv48Dd Designer Door Installation

    MQZCV39DD / MQZCV42DD / MQZCV48DD Designer Door Installations Each Kit contains: Back Frame, Front Frame, and Screen.  If protruding facing materials (i.e., concrete board, brick or tile) are to be used, refer to Facing Material Dimension Requirements section.  Designer Doors require a minimum 1/8”...
  • Page 22: Zcv-Tlk Optional Tile Lip Kit

    MQZCV48 -TLK Optional Tile Lip Kit Contents of Kit: Qty. [4] Tile Lip pieces 47” long, Qty. [12] screws. Instructions: Refer to the charts below to find your installation choice. -Cut [2] tile lip pieces to height of sides, and [2] to length of top & bottom. -Install onto face of fireplace so that screwing flange will be beneath facing materials.
  • Page 23: Mqzcv48 Mantel Clearances

    MQZCV48 Mantel Clearances Before installing any mantels it is Mantel Dimensions are from front important to determine the face or Non-Combustible Facing combustibility of its material(s). There Materials covering fireplace. are two types of mantels to consider: Combustible and Non-Combustible. A Combustible Mantel is one that Optional Recess 3/4”...
  • Page 24: Mqzcv48 - 51Uhs Box

    MQZCV48 51UHS Box Included with base model. The 51-UHS is designed for millivolt and IPI units for in-unit installation of the Remote Receiver, Fan Control Module, and the IPI Module. 51-UHS can be inserted & removed from beneath fireplace through access panel opening (Remove glass door first).
  • Page 25: Component Locations

    TRANSFORMER NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC. Since some municipalities have additional local codes, it is always best to consult your local authorities and the current...
  • Page 26: Mqzcv48 - Z46Fk Fan Kit Installation

    ZCV39 / ZCV42 / MQZCV48 Z46FK Fan Kit Installation ⚠ WARNING The fan can be installed through the side of the fireplace. Electrical Grounding Instructions This appliance is equipped with a three prong (grounding) plug for your protection against If fireplace is already installed, the shock hazard and should be plugged directly into a properly grounded three-prong burner pan must be removed to receptacle.
  • Page 27: Fan Speed Control Outside Of Fireplace

    Split Receptacle- Fan Speed Control Outside of Fireplace If you plan to locate the variable speed control switch for the fan outside of the fireplace and you require a constant source of AC power inside the unit for another accessory such as lights or an IPI valve system, follow one of the procedures below.
  • Page 28: Zcv48Pl Porcelain Liner Installation

    ZCV48PL Liner Installation ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. PARTS LIST: [1] – Back Liner [1] –...
  • Page 29: Zcv48Rlt / Zcv48Rlh / Mqzcv48Rlf Liner Installation

    ZCV48RLT / ZCV48RLH / MQZCV48RLF Liner Installation PARTS LIST: [1] – Back Liner [1] – Left Side Liner [1] – Right Side Liner ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or...
  • Page 30: Mqzcv48Gt Glass Tray Setup

    MQZCV48GT Glass Tray Setup Parts List: [1] Glass Tray with attached Pilot Shield NOTE: for use with brick liners see next page - Cutting Liners for use with Glass Tray – STEP 1: Remove Log Holder, Ember Tray, and Log Grate. Log Holder Ember Tray Log Grate...
  • Page 31: Cutting Liners For Use With Glass Tray

    MQZCV48GT Cutting Liners for use with Glass Tray Cut shaded areas off and discard. Liners will sit on top of Glass Tray.
  • Page 32: Ulk4 Universal Light Kit

    MQZCV48 ULK4 Universal Light Kit ( Optional Accent Lighting Kit) Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada. Contents of Kit:  [4] 12V Halogen Lamps  Lamp Plate with Insulated Studs & wiring ...
  • Page 33 Screw Screw Screw Screw Lamp Plate Lamp Setup for MQLOGF48 Oak Log Set , MQLOGF48D Driftwood Log Set: STEP 3: Place Lamps in firebox as shown above. Rear Lamps face back wall of firebox, and front lamps are pointed upward. Attach Lamp Mount Brackets to fireplace with [2] screws at the locations shown. Replace Burner, Ember Plate, and Grate Bar.
  • Page 34: Mqlogf48 Oak Log Set

    MQZCV48 MQLOGF48 Oak Log Set ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only LOG 1 parts specifically approved with this appliance may LOG 3 LOG 2 result in property damage or personal injury LOG 4 *NOTE: THESE ITEMS ARE SUPPLIED WITH THE FIREPLACE:...
  • Page 35 STEP 4 LOG 6 is placed in front of LOG 2. LOG 7 is in front of LOG 3. LOG 8 hooks onto Grate Bar as shown. Place LOG 8 between the LOG 3 LOG 2 Grate Bars on the right side.
  • Page 36: Mqlogf48B Burnt Oak Log Set

    MQZCV48 MQLOGF48B Burnt Oak Log Set *NOTE: THESE ITEMS ARE SUPPLIED WITH THE FIREPLACE: LOG 3 *Lava Rock LOG 9 LOG 4 LOG 2 *Embers LOG 8 LOG 5 *Vermiculite LOG 7 LOG 1 LOG 6 *Insulation Wool STEP 2 STEP 1 LOG 1 LOG 3...
  • Page 37 STEP 5 LOG 9 LOG 8 LOG 7 Place LOG 7, LOG 8, and LOG 9 as shown. ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury...
  • Page 38: Rbcb1 Cannonballs

    RBCB1 -Cannonballs- Installation Instructions *Must be used with MQZCV48GT Glass Tray Assorted size and colors. Place randomly as desired inside fireplace. Can be used with MQ Glass, MQ Ember, and / or Lava Rock. Do not place Cannonballs directly on burner ports. If sooting occurs change position of or remove affected objects.
  • Page 39: Mq Dealer Accessories For Mqzcv48

    MQ Dealer Accessories for MQZCV48 The following Accessories are available through MQ Dealers only. GLASS (MQG5W, MQG5C, MQG5A, MQG5B, MQG5ZG) ACCESSORY ITEM DESCRIPTION  If you wish to use this media evenly spread the glass embers onto the false bottom and burner. Ensure the glass embers do not excessively MQG5W* Decorative Glass 1/2”...
  • Page 40 MQROCK2, MQROCK3 - Must be used with Glass Tray MQZCV48GT MQ EMBER MQRock2 (shown) can be placed on Burner. MQ Glass can be MQRock3 placed on Burner and Glass Tray. Lava Rock (Supplied with Base Unit). Do not place on Burner. ⚠...
  • Page 41: Mqlogf48D Setup

    MQZCV48 MQLOGF48D ⚠ WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. *These items are supplied with the fireplace. *Lava Rock *Insulation Wool *Embers...
  • Page 42 Embers, Lava Rock & Lava Rock & Vermiculite Insulation Wool on Burner on Firebox Bottom If Crushed Glass and Light Kit are used, place Glass onto front area of Burner and over left and right rear lights.
  • Page 43: Mqzcv48 Door Installation

    MQZCV48 Door Installation To install Door: 1. Remove Access Cover below Glass Door. 30° 15° 2. Engage door in lower latches at an angle of between 15 and 30 degrees. 3. Swing door up and pull top latches over door lip at each corner. Door Bottom Latch ⚠...
  • Page 44: Door And Glass Information

     Do not strike or abuse the glass. Glass Replacement MQZCV48N, MQZCV48LP, MQZCV48NE, MQZCV48LPE must use tempered glass. Must be 5mm thick. To replace glass, clean all materials from the door frame. Scrape off old silicone all the way down to the metal. Using high-temp silicone [rated up to 500°F (260°C)] apply a continuous bead of approximately 1/8”-3/16”...
  • Page 45: Gas Line Installation

    1/2 PSIG (3.5 KPa). NOTE: The gas line connection may be made of 1/2” rigid pipe or an Approved Kingsman Flex Connector, such as FP15GC.
  • Page 46: Millivolt System, Lighting, And Burner Control

    Millivolt System, Lighting, and Burner Control FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. BEFORE LIGHTING This appliance has a pilot which must be lighted by hand. When ...
  • Page 47: Annual Inspection List

    Annual Inspection List for Determining Safe Operation of a Direct Vent Gas Fireplace Refer to this checklist for proper maintenance, safe use, and operation. See each section for more specific information. 1. Inspect and operate all pressure relief mechanisms (i.e., relief dampers, spring loaded door latches) installed on your appliance to verify relief mechanisms are free from obstruction to operate.
  • Page 48: Troubleshooting The Gas Control System

    Troubleshooting the Gas Control System ⚠ WARNING BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE THE GLASS FRONT. NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the "On" position. Problem Possible Causes Corrective Action Spark igniter will not Defective or misaligned Check for spark at electrode and pilot: if no spark and electrode wire is...
  • Page 49: Burner System Maintenance

    Burner System Maintenance It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This operation should be performed by your dealer or a qualified technician. -CAUTION- Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections to the appliance.
  • Page 50 Gas Conversion Part A MQZCV48 IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK TESTING. Main Burner Air Shutter & Screw Pilot Orifice Main Burner Orifice Brass Nipple Parts List: ...
  • Page 51: Gas Conversion Kit For Top Convertible Pilot Part B

    Gas Conversion for Top Convertible Pilot – Part B (series 0190XYZ) Instructions for converting SIT 190 series pilot burner injector from NG to LPG and from LPG to NG only. This information should be considered as supplemental to the Appliance Manufacturer's Instructions. WARNING! The installation of this conversion kit must only be undertaken by a qualified and certified gas appliance installer.
  • Page 52: Gas Conversion For Modulator - Part C

    Gas Conversion for Modulator – PART C...
  • Page 53: Burner Removal / Burner System Removal / Installation

    MQZCV48 Burner Removal Burner 1. Remove Log Grate. Remove two [2] screws from grate bar assembly. 2. Remove Ember Plate. Remove [2] screws. Ember Plate 3. Remove Burner. Remove four [4] screws from burner. Slide burner to the left and lift to remove.
  • Page 54: Ipi Electronic Ignition System

    IPI Electronic Ignition System Overview Cover The IPI system is an advanced burner controller that provides you with the option of having either a Standing- Pilot, or an intermittent igniting system. This alternating Backup mode is controlled by the CPI/IPI Switch (Continuous Pilot Battery Ignition/Intermittent Pilot Ignition) located on the IPI System Pack...
  • Page 55: Remote Control Operation

    -Remote Control Operation- The Proflame GTM is configured to control the on/off main burner operation, its flame levels, and provides on/off and Smart thermostatic control of the appliance. Transmitter Remote Receiver Transmitter Room Thermostat ( Transmitter Operation) The Transmitter is powered by 3 AAA type batteries. A Mode The Remote Control can operate as a room thermostat.
  • Page 56: Ipi Electronic Ignition Parts List - Standard System

    IPI Electronic Ignition Parts List – Standard System ITEM NO. PART NO. DESCRIPTION 1006-P002si Valve IPI Hi/Lo NG 1006-P003si Valve IPI Hi/Lo LP *1002-P047si Pilot Assembly-LP -24” Wire *1002-P033si Pilot Assembly-NG -24” Wire 1002-P017si Spark Electrode (with wire) *1002-P119si Spark Electrode (with wire- 35” Length) 1002-P903si Electrode Flame Sensor *1002-P910si...
  • Page 57: Configuration 1: Basic Manual Hi / Lo And Manual Off

    Configuration #1: Basic manual HI/LO and manual ON/OFF capabilities.
  • Page 58: Configuration 2: Remote On / Off And Manual Hi / Lo

    Receiver Module .584.523/521/221 1001-P221SI Receiver Module .584.523/521/221 1001-P221SI...
  • Page 59: Operating The Receiver Without Batteries For Gt / Egt / Gtm / Egtm Remote Controls

    Operating the Receiver Without Batteries For GT / EGT / GTM / EGTM Remote Controls -Wiring Harness P/N 1002-P906si required for both IPI & Millivolt systems. -Millivolt Systems will also require Power Adapter P/N 1002-P850si. The Remote Receiver & IPI or Millivolt system can be powered by the AC Adapter. This is advantageous if you do not want to use batteries.
  • Page 60: Configuration 3: Remote On/Off, Variable Hi/Lo, And Fan

    Configuration #3: Remote ON/OFF, variable HI/LO, and fan capabilities. Refer to the fan installation/removal section for fan installation.
  • Page 61: Electronic Ignition Lighting Instructions

    Electronic Ignition Lighting Instructions If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Always light the pilot whether for the first time or if the gas supply has ran out with the glass door opened or removed. FOR YOUR SAFETY READ BEFORE LIGHTING: A.
  • Page 62: Ipi System

    Proflame 2 –NE2 / LPE2 -IPI System Parts List- IPI PROFLAME 2 - COMPONENT PARTS IPI - PF1 and PF2 Common Components PART NO. DESCRIPTION PART NO. DESCRIPTION 1005-P001SI Valve IPI Proflame PF2 885.001 NG - Stepper 12. 1002-P033SI TC - Pilot Burner IPI (Assembled) NG 199.033 1005-P002SI Valve IPI Proflame PF2 885.002 LP - Stepper 13.
  • Page 63: Proflame 2 Ifc Module And Remote Control

    Proflame 2 IFC Module and Remote Control LCD Display ON / OFF Key Thermostat Key Batteries UP / DOWN Arrow Key Mode Key IFC Module Button  Within 10 seconds press the button again until Pairing Remote Control: you hear it beep. ...
  • Page 64: Cold Climates - Cpi Setting - Proflame 2 Remote Control

    Cold Climates – CPI Setting - Proflame 2 Remote Control Use the CPI setting during cold weather, otherwise the fireplace may have a hard time starting up and establishing a flame. The CPI (Continuous Pilot Ignition) setting will keep the firebox and fireplace exhaust vent warm during cold weather. When the firebox and exhaust vent are warm, exhaust gasses will readily flow out of the firebox.
  • Page 65: Proflame 2 Remote Control Operation

    Proflame 2 Remote Control...
  • Page 66 Note: When Smart Thermostat is activated, manual flame height adjustment is disabled. Note: This function is only available in Room Thermostat or Smart Thermostat Control Mode.
  • Page 68: Vent Terminal Clearances

    Vent Terminal Clearances Clearances are to the edge of the terminal plate. Add 6-3/4” to clearances to arrive at centerline. Local codes or regulations may require different clearances. WARNING: A HORIZONTAL VENT CERTIFIED GUARD (SAFETY CAGE) IS AVAILABLE WHEN REQUIRED BY LOCAL CODES. Canadian installations US installations Clearance above grade, veranda,...
  • Page 69: General Vent Installation

    General Vent Installation Information This gas appliance is approved to be vented either through the side wall or vertically through the roof. Only Kingsman Flex (Z-Flex) Venting Kits and components specifically approved and LABELED for this stove may be used. This appliance is also approved for use with 5 x 8 M&G-Duravent Direct Vent system (Model DV-GS Series), BDM Pro Form Direct Vent, Ameri-Vent Direct Vent Pipe System, ICC Excel Direct, Metal Fab Sure-Seal DV and Selkirk Direct Temp.
  • Page 70: Venting Routes And Components

    Venting Routes And Components Venting Routes and Components Since it is very important that the vent system maintain its How to Use the Horizontal Vent Table balance between the combustion air intake and the flue gas 1. Determine the height of the system and the number of exhaust, certain limitations as to vent configurations apply and bends required.
  • Page 71: Venting Straight Up Through Roof

    Venting Straight Up Through Roof An Attic Insulation Shield must be installed where the vent passes from a lower living space into an attic space where the chimney is not enclosed. It is designed to keep insulation materials away from the chimney. When installing the Attic Insulation Shield where the chimney passes from a living space to an attic space, install the shield from below and nail in place using 1"...
  • Page 72 -Restrictor- Remove for Runs Under 15 Feet Clearances in horizontal venting. Z58VT Clearance to perpendicular wall 24 inches (60 cm). (Recommended to prevent re- circulation of exhaust products. For additional requirements check local codes.) 24” 18” MIN Clearance above highest point of exit on roof 18 inches (45cm) 43ft...
  • Page 73: Approved For Power Vent Pvh58

    Approved for Power Vent PVH58 - This appliance is approved for use with the Kingsman PVH58 Horizontal Power Vent - The PVH58 Horizontal Power Vent Termination is intended for use where standard venting configurations are not possible. NOTE: MODELS EQUIPPPED WITH MILLIVOLT/ STANDING PILOT IGNITION: Downward vertical vent runs are NOT permitted.
  • Page 74: Pvh58 Parts List

    PVH58 Parts List PVH58 HORIZONTAL POWER VENT TERMINATION: Listed for Canada and USA NUMBER DESCRIPTION MQZCV48 VENTING AND VENTING ADAPTERS -For fireplaces to be converted to hard pipe (M&G-Duravent-DirectVent Pro, etc.) at the fireplace: Z58DFA M&G-Duravent Fireplace Adapter -For Power Vent installations where flex pipe will be used up to the Power Vent unit: Z58PVA Flex Connector Set- ZDV5FC (5”...
  • Page 75: Zcv48 Parts List

    Fan Kit w/Variable Speed Wall Mount MQZCV48N (Millivolt) Fireplace Heater rated, NG, Control (Temperature Sensing) Tempered Glass, Safety Screen 26IDV-P260 Blower Motor (Replacement) MQZCV48NE (IPI) Fireplace Heater Rated NG, Tempered Safety Screens Glass, Safety Screen ZCV48CSS Safety Screen Replacement MQZCV48NE2...
  • Page 76 Thermalcord - Adhesive Back for Door 1000-306 Frame Control Variable Speed KBWC-13BV 1000-085 FP15GC Stainless Steel Gas Connector Kingsman Fireplace Venting Z58DFA M&G-Duravent Adapter (5 x 8) Vertical Vent Termination Z58VT Horizontal Vent Termination Z58HT Safety Cage for Horizontal Termination...
  • Page 77: Limited Lifetime Warranty

    During the first year after installation, we will provide a replacement for any component part of your unit found to be defective in materials or workmanship, including labour costs. Repair work requires prior approval by Kingsman, labour costs are based on a predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer.

This manual is also suitable for:

Mqzcv48nMqzcv48lpMqzcv48ne2Mqzcv48lpe2Mqzcv48lpe

Table of Contents