Remote Control; Emptying The Internal Water Container - Amcor 9KE(H)-410 English Instruction Manual

Plmb mono blocs
Hide thumbs Also See for 9KE(H)-410:
Table of Contents

Advertisement

• Remove the active carbon filter (black) from its plastic bag.
• Insert the active carbon filter into the filter holder (see fig. 2).
• Fix the filter by reassembling the fixer into the filter holder (see fig. 3).
NOTE!
• Remove active carbon filter before seasonal storage and install new filters at the beginning of the
new season. The old filters can be disposed in the 'Non-biological garbage container' .
• Replacement filter packages are available directly from Amcor.
• To run the unit without active carbon filter does not do any harm to the air conditioner. In this case
odours and unhealthy dust are not removed from the circulated air.
• The screen filter must always be used.

REMOTE CONTROL

The unit responds to all signals that are sent by the remote control. There will be
a beep sound from the unit after receiving the signal.
The operation of the unit by remote control, is almost identical to the operation
by the circular control panel. The only exception is the clock function.
Instead of the
button for setting the actual time and for programming the
timer, there are 3 push buttons on the remote control as follows:
- for setting the actual time.
• TIMER ON - for programming the time when the unit is ON.
• TIMER OFF - for programming the time when the unit is OFF.

EMPTYING THE INTERNAL WATER CONTAINER

Under high humidity conditions it may be necessary to empty the internal
water container. When the internal water container is full the backlight
on teh LCD-display flashes. the unit will switch off automatically.
To empty the water container do the following:
• Switch off the unit and remove the plug from the wall socket.
Do not move the unit. Doing this can result in water leakage,
damaging your floor or carpet.
• Place the water container on the floor underneath the permanent
drainage point.
• Remove the water stopper and rubber plug from the drain and let the
water run out. The water container has to be emptied several times
before all water will be drained (ca. 1.5 litres).
• Replace the rubber plug and water stopper, put the plug into the wall
socket, and switch the unit on.
The warning signal should be off.
NOTE! When the air conditioner is in use, under normal circumstances the condensed water will
evaporate and then be discharged through the hot air outlet hose
AT
HOURS:MINUTES
TEMPERATURE
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents