Installation; Electrical Requirements - DeLonghi DOMFP/S Installation And Service Instructions Use And Care Instructions

Double oven
Table of Contents

Advertisement

CAUTION:
In order to avoid a hazard this appliance must be installed
according to these instructions for installation.

ELECTRICAL REQUIREMENTS

Connection to the mains must be carried out by qualified personnel in
accordance with current regulations.
The appliance must be connected to the mains checking that the voltage
corresponds to the value given in the rating plate and that the electrical
cable sections can withstand the load specified on the plate.
The appliance must be connected directly to the mains placing an omnipolar
switch with minimum opening between the contacts of 3 mm between the
appliance and the mains.
The power supply cable must not touch the hot parts and must be
positioned so that it does not exceed 75°C at any point.
Once the appliance has been installed, the switch or socket must always be
accessible.
If the power supply cable is damaged it must be substituted by a suitable
cable available in the after sales service.
WARNING This appliance must be earthed.
4

INSTALLATION

1131125
TOP OVEN
F2
Oven commutator
E2
Oven thermostat
S2
Thermostat pilot lamp
LF2
Oven lamp
C1
Top element
G1
Grill element
S1
Bottom element
TL1
Oven thermolimitator
BOTTOM OVEN
F1
Oven commutator
E1
Oven thermostat
S1
Thermostat pilot lamp
PR
Oven programmer 1P
LF
Oven lamp
C
Top element
G
Grill element
V
Fan
S
Bottom element
CIR
Circular element
TL2
Oven thermolimitator
M
Terminal block
T
Earth plant