N.B. For connection to the mains, do not use adapters, reducers or branching
devices as they can cause overheating and burning.
If the installation requires alterations to the domestic electrical system call an expert.
He should also check that the socket cable section is suitable for the power absorbed
by the appliance.
CONNECTING THE FEEDER CABLE
Remove the two screws that hold shield A behind the oven.
Open completely the cable clamp C
Insert the feeder cable (type H05 RR-F) of minimum 2,5 mm
the cable save P.
Connect the phase and earth cables to terminal B according figure 1.
The wires of this appliance must be coloured in accordance with the following code:
GREEN AND YELLOW - EARTH
BLUE - NEUTRAL
BROWN - LIVE
The wire which is coloured GREEN AND YELLOW must be connected to the terminal
which is marked with the letter "E" or by the Earth
or GREEN AND YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is marked
with the letter "N" or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is
marked with the letter "L" or coloured RED.
Pull the feeder cable and block it with the cable clamp C.
Re-mount shield A.
Brown
(Live)
C
Figure 1
L N
Blue
(Neutral)
P
2
section into
symbol or coloured GREEN
B
Green &Yellow
(Earth)
A
5