6.

Fault diagnosis/ What to do if ...?

6.1

Alarmmanagement (Faultcodes)

Alarmmanagement Powerboards Prisma, OVC1000 und OVC2000
Display
Description of fault
Internal error
F0
F1
door cannot be locked
F2
door cannot be unlocked
software error
F3
F94
Temperature sensor alarm - resulting in F4
F4
Temperature sensor without contact or short circuit Test temperature sensor, replace if necessary
Clotted heating element relay contacts on the
F5
power electronics
Temperature alarm at power electronics - resulting
F95
in F6
F96
Temperature alarm at power electronics - resulting
in F6
Power electronics temperature too high
F6
Faulty electrical connection (only in appliances
F7
with Prisma power electronics)
F8
No connection between power electronics and
input electronics
Micro processor resets itself independently (=
F9
Reset)
F10
Triac on power electronics defect
Meat skewer sensor without contact or short-
F11
circuited
F91
Temperature sensor alarm for steam generator -
resulting in F12
Temperature sensor of steam generator without
F12
contact or short-circuited
F13
Internal electronics error
F14
software error
Internal electronics error
F15
Combined alarm Pyrolytic cleaning/cooking zone
F16
6.2

Demo Mode input electronic Avantgarde

6.2.1 Activating/deactivating Version a

Disconnect appliance approx. 10 sec from the supply mains. After the renewed connection „time of
day" is lit, the display indicates „12.00" . Now actuate the „selection" key, afterwards activate the
demo mode by pressing together with the „selection" and „minus" key simultaneously within 2 sec.
For deactivating the demo mode please proceed in the same order.
The active demo Mode is confirmed by the time symbol in the display. When activating the Demo
Mode, please make a mental note of the positions of the „Selection" and „Minus" keys as these
have to be pressed once more in order to deactivate the Demo Mode but it is possible that these
arte not visible, depending on the date of manufacture and software version.
DGS-TDS-N 05.09 A. B. © Electrolux
Fault repair
replace power electronics
Test door locking system
Test door locking system and unlocking thermostat
f11
Execute network reset by disconnecting the
appliance from the electricity supply and restarting
Test temperature sensor, replace if necessary
Replace power electronics
Test built-in situation of the ventilation channel and
the function of the cooling fan
Test built-in situation of the ventilation channel and
the function of the cooling fan
Test built-in situation of the ventilation channel and
the function of the cooling fan
Correctly connect the appliance and re-start
Check connection line - replace electronic systems if
necessary
Execute network reset by disconnecting the
appliance from the electricity supply and restarting
Activate Main Button, select an operation modus
with hot air, wait for cooling ventilation start, replace
power electronics again in the event of an error report
following approximately 20 seconds
Check meat thermometer, also check bushing and
wiring if necessary; if all this OK replace power
electronics
Test temperature sensor, replace if necessary
Test temperature sensor, replace if necessary
Replace power electronics
Replace input electronics
Replace input electronics
Replace input electronics
- 17 -