Service And Adjustments; To Replace Or Clean Check Valve - Delta 66-501-1 Instruction Manual

Oil-free air compressor
Hide thumbs Also See for 66-501-1:
Table of Contents

Advertisement

compressed air or moving parts. Personal injuries can occur. Before
performing any Maintenance or repair, unplug the compressor and bleed
off all air pressure.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE
PERFORMED BY TRAINED SERVICE TECHNICIAN.
• Unplug or disconnect electrical supply to the air compressor.
• Bleed tank of pressure.
• Allow the air compressor to cool.

To Replace or Clean Check Valve

1.
Release all air pressure from air tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug outfit.
3.
Loosen the nut on the outlet tube
and move the outlet tube to the
side.
4.
Unscrew the check valve (turn
counterclockwise) using a socket
wrench.
5.
Make sure the valve disc moves
freely inside the check valve and
the spring holds the disc in the
upper, closed position. The check
valve may be cleaned with a
solvent, such as paint and
varnish remover.
6.
Apply sealant to the check valve
threads. Reinstall the check valve
(turn clockwise).
7.
Replace the outlet tube and tighten
the nut.
8.
Perform the Break-in Procedure. See "Break-in Procedure" in the
Operation section.

SERVICE AND ADJUSTMENTS

Unit cycles automatically when power is on. When doing
Maintenance, you may be exposed to voltage sources,
Before servicing:
Outlet Tube
In open
position
nothing is
visible.
15- ENG
Nut
Check
Valve
Screwdriver
In closed position
disc is visible.
D29682

Advertisement

Table of Contents
loading