Delta (66-501-1) Instruction Manual
Delta (66-501-1) Instruction Manual

Delta (66-501-1) Instruction Manual

Oil-free air compressor
Hide thumbs Also See for (66-501-1):

Advertisement

To learn more about DELTA MACHINERY
visit our website at: www.deltamachinery.com.
For Parts, Service, Warranty or other Assistance,
please call 1-866-422-4286.

Air Compressor

PART NO.
Copyright © 2004 Delta Machinery
Oil-Free
(66-501-1)
A08591
Rev. 0 11/04
ESPAÑOL: PÁGINA 25
FRANÇAIS: PAGE 49

Advertisement

Table of Contents
loading

Summary of Contents for Delta (66-501-1)

  • Page 1: Air Compressor

    To learn more about DELTA MACHINERY visit our website at: www.deltamachinery.com. For Parts, Service, Warranty or other Assistance, please call 1-866-422-4286. Oil-Free Air Compressor (66-501-1) A08591 PART NO. Copyright © 2004 Delta Machinery ESPAÑOL: PÁGINA 25 FRANÇAIS: PAGE 49 Rev. 0 11/04...
  • Page 2: Safety Guidelines - Definitions

    SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these symbols.
  • Page 3 IMPORTANT SAFETY INSTRUCTIONS Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire What Could Happen It is normal for electrical contacts within the motor and pressure switch to spark.
  • Page 4 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen WARNING: Risk from Flying Objects The compressed air stream can cause soft tissue damage to exposed skin and can propel dirt, chips, loose...
  • Page 5 WARNING: Risk of Electrical Shock What Could Happen Your air compressor is powered by electricity. Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
  • Page 6 WARNING: Risk of Burns Touching exposed metal such as the compressor head or outlet tubes, can result in serious burns. A08591 Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation. Do not reach around protective shrouds or attempt maintenance until unit has been allowed to cool.
  • Page 7 WARNING: Risk of Unsafe Operation What Could Happen Unsafe operation of your air compressor could lead to serious injury or death to you or others. SAVE THESE INSTRUCTIONS HAZARD...
  • Page 8: Duty Cycle

    A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit the air compressor is operated on. If compressor is connected to a circuit protected by fuses, use only time delay fuses. Time delay fuses should be marked "D"...
  • Page 9: How To Set Up Your Unit

    HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling.
  • Page 10: Extension Cords

    RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see illustrations).
  • Page 11: Voltage And Circuit Protection

    Voltage and Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requirements. Certain air compressors can be operated on a 15 amp circuit if the following conditions are met. Voltage supply through branch circuit is 15 amps. Circuit is not used to supply any other electrical needs (lights, appliances, etc.).
  • Page 12: Know Your Air Compressor

    You know that the cooling system is working when air is being expelled. Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.
  • Page 13: How To Use Your Unit

    This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. Make sure the On/Auto/Off lever is in the "Off" position.
  • Page 14: How To Start

    When the desired pressure is reached push knob in to lock in place. The compressor is ready for use. NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.
  • Page 15: To Replace Or Clean Check Valve

    Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure. To Replace or Clean Check Valve Release all air pressure from air tank.
  • Page 16: To Replace Regulator

    Reapply pipe sealant to gauges and hose. Reassemble gauges and hose. Orient gauges to read correctly. Tighten hose with wrench. Before you store the air compressor, make sure you do the following: Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary.
  • Page 17: Troubleshooting

    Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM...
  • Page 18 Decrease amount of air usage. Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Check and replace if required. Remove and clean, or replace. Tighten fittings.
  • Page 19 PROBLEM Motor will not Fuse blown, circuit breaker run. tripped. Extension cord is wrong length or gauge. Loose electrical connections. Faulty motor. CAUSE Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
  • Page 20: Air Compressor Diagram

    AIR COMPRESSOR DIAGRAM * IMPORTANT: Some models were built with a check valve and bushing reducer. If check valve needs to be replaced, remove the old check valve and reducer bushing before replacing with the preferred one piece check valve (Key 18).
  • Page 21: Parts List

    Key No Part Number TIA-4150 A06891 CAC-4299 CAC-60 SSF-8080-ZN AC-0345 SSF-612 AC-0364 Z-D27227 D26615 D28999 D30198 D27256 Z-AC-0009-1 Z-AC-0010-1 Z-D25895 SSP-473 D29264 CAC-1254 SSF-621 PARTS LIST Description Safety Valve Drain Valve Wheel 6" (2) Shoulder Bolt (2) Nut Hex 3/8-16 (2) Handle Screw #10-16 x 1(2) Molded Foot Bumper...
  • Page 22: Air Compressor Pump Diagram

    AIR COMPRESSOR PUMP DIAGRAM 9-10 9-11 9-12 Torque 30 in.-lbs. 9-13 A08591 Torque 30-45 in.-lbs. 22- ENG Torque 49-55 in.-lbs. Torque 10 in.-lbs. Max...
  • Page 23 Part No. ----- ★ ----- ★ ----- CAC-1212 ▲ ----- ▲ Z-A08548 DAC-269 ----- ▲ Z-A04647 ----- ◆ • ----- 9-10 ----- • 9-11 D21127 9-12 SSF-3147 • ◆ 9-13 ----- CAC-1206-1 SUDL-9-1 SSF-3156 A00765 D25731 SSF-995 AC-0206 Z-D23701 AC-0815 Not Illustrated KK-4964 ◆...
  • Page 24: Limited Warranty

    Delta, or unauthorized repair or alterations. * An air compressor that pumps air more than the recommended duty cycle during a one hour period may be considered misuse. • Repair and transportation costs of merchandise determined not to be defective.

Table of Contents