Advanced Setup
On
Select the display back-
light always On, or Off
after 8 seconds.
Off
C
Select thermostat
operation in degrees
Fahrenheit or
Centigrade.
F
DEHUMIDIFICATION - There are 2 methods of Dehumidification:
1) Using your A/C to dehumidify (see below and next page).
2) Using the Dehum Terminal (see page 20).
COOL TO DEHUMIDIFY - If Cool to Dehumidify is ON, the thermo-
stat has the ability to initiate a cooling cycle for advanced dehu-
midification operation. When the thermostat detects a humidity
percentage above the setpoint for dehumidification, and heating
or cooling is not on, the thermostat will force the compressor to
run with the fan, thus reducing moisture in the air. This feature
will allow you to adjust the cooling overshoot of the setpoint, 0
to 5 (adjustable in step #20, next page).
°
cooling overshoot is set for 3 F and the cooling setpoint is set for 74 F,
then as long as the room temperature reads between 71 F and 74 F
this feature will energize the compressor and fan to dehumidify the air.