Advanced Setup
MULTI-STAGE OPERATION - Control up to 2 Heat, 2 Cool Stages
The 2nd Stage of heat or cool is
(A) the 1st Stage has been on for two minutes and
(B)
the setpoint plus the 1st stage deadband (two degrees)
plus the 2nd stage deadband. This 2nd stage deadband
is adjustable from 1-6 degrees and the default is two
degrees.
Heating
2nd Stage
turn on
Adjust the deadband
( 1 - 6 )
MINIMUM HEAT/COOL SETPOINT DIFFERENCE -
The Heat and Cool setpoints will not be allowed to come any
closer to each other than the value in this step. This minimum
difference is enforced during Auto Changeover operation.
Adjust the minimum
difference between
cooling & heating
setpoints.
(0 - 6 )
turned on when:
Dead
Dead
Band
Band
2 degrees
2 degrees
1st Stage
1st Stage
Heat
Cool
turn on
Setpoint
Setpoint
turn on
I0
2
Setup
I I
2
Setup
COOL
HEAT
Continued
Page 15
Cooling
2nd Stage
turn on
Press
MODE
Press
MODE