Battery - Gasoline Vehicles - Club Car DS Golf Car Owner's Manual

Electric and gasoline
Table of Contents

Advertisement

Refilling the Batteries
1.
Locate the battery fill coupling (9) on the driver side of the battery compartment, remove the dust cover (10)
from the male connector (Figure 28), and connect the hose-end assembly (3) (Figure 29). The water flow
will begin immediately.
70
Figure 28 Dust Cap
2.
The red flow indicator balls should swirl, indicating that the batteries are being filled. See following CAUTION.
CAUTION
• If at any time water overflows from the batteries, immediately stop the refill process, disconnect the
pressure regulator from the battery fill coupling, and call for service.
3.
When the red flow indicator balls stop moving, immediately press the grey button to disconnect the hose-end
assembly from the battery fill coupling (9), and squeeze the dust cover (10) to lightly secure it to the male
connector of the battery fill coupling (Figure 28).
4.
Place the battery fill coupling into the space between the battery bucket and the car body. Leaving the fill coupling
on top of the battery bank or tucked between the batteries and the battery bucket can result in coupling damage.
5.
Turn the water faucet off when finished filling the vehicle(s).
BATTERY – GASOLINE VEHICLES
See General Warnings on page 9.
DANGER
• Battery – Explosive gases! Do not smoke. Keep sparks and flames away from the vehicle and service
area. Ventilate when charging or operating vehicle in an enclosed area. Wear a full face shield and
rubber gloves when working on or near batteries.
DANGER CONTINUED ON NEXT PAGE
9
10
71
Figure 29 Connecting Hose-end Assembly to Battery Fill
Connector
DS Golf Car Owner's Manual
Battery – Gasoline Vehicles
9
3
Page 47

Hide quick links:

Advertisement