Installation

KTD-400 &
KTD-300R
CAUTION:

Setting the DIP Switch

Mounting the
KTD-300R
1034790D / January 2001
Installing a KTD-400 keypad involves setting the DIP switch, mounting the unit (KTD-300R
only), and making cable connections.
NOTE: To incorporate a KTS-41A switcher into a KTD-400 system, refer to the installation
sheet provided with the DTMF Upgrade Kit.
Do not connect power to the unit before all installation steps have been completed.
Do not connect directly to a telecommunication network.
The KTD-400 contains a DIP switch that is used to select mode of operation choices as
shown in Table 1. To change the switch from factory settings, refer to Figure 3.
Table 1: DIP Switch Settings
Setting:
Description:
Digiplex P/T/Z and VCR control only.
Multiplexer control only.
Factory setting: Digiplex P/T/Z, multiplexer, and VCR control.
Controlling a Robot MV96 multiplexer with a KTD-90.
Figure 3: KTD-400 and 300R Cover Removal and DIP Switch Location
KTD-400
The KTD-300R is designed to fit into a standard EIA 19" rack and uses one unit (1.75") of
rack space. Mount the unit using the four holes in its front panel and hardware provided from
the rack manufacturer.
KTD-300R
7