Installation Highlights - GE WSLS1100 Technical Service Manual

Wsl series
Table of Contents

Advertisement

Location
Washer must be installed on firm flooring.
Concrete flooring is best, but wood base is
sufficient providing floor support meets FHA
standards.
Washer should not be installed on rugs or
exposed to the weather.
Install or store washer where it will not be
exposed to temperatures below freezing.
Minimum clearances between washer and
adjacent walls or other surfaces are:
0" either side, 2" front, 3" rear.
Minimum vertical space from floor to over-
head shelves, cabinets, ceilings, etc., is 96".
Closet doors must be louvered or otherwise
ventilated and have at least 60 square
inches open area for washer only, or if the
closet contains both a washer and dryer,
doors must contain at least 120 square
inches of open area equally distributed.
Laundry Tub
Plumbing
Water pressure must be 10 psi minimum to 150 psi maximum dynamic pressure measured at
faucet.
Water temperature on household water heater should be set to deliver water at 120° to 150°F
(50° to 66°C) in the washer when HOT wash is selected.
Shut-off valves should be supplied for both hot and cold water lines.
Drain water into a standpipe or laundry tub. The discharge height must not be less than 30" nor
more than 8' above the base of the washer. The standpipe must be 1-1/2" minimum inside diam-
eter and must be open to the atmosphere.
Electrical Wiring
National Electrical Codes or prevailing local
codes and ordinances must be followed.
120V, 60Hz must be supplied and connected
to an individual, properly grounded branch
circuit, protected by a 15- or 20-amp circuit
breaker or time delay fuse.
Wiring must be 2-wire with ground.

Installation Highlights

Note: The clearances stated are minimums.
Consideration must be given to providing
adequate clearances for installation and
servicing.
Cable Tie
GEA00044
Electrical Rating
For use on adequately wired 120-volt, 15-amp circuit having
2-wire service with a separate ground wire. This appliance
must be grounded for safe operation.
– 3 –
60 sq. in.
(387.1 sq. cm)
60 sq. in.
(387.1 sq. cm)
Closet door
GEA00046
Cable Tie
Stand Pipe
Voltage AC ............................................................ 120
Hertz ....................................................................... 60
Total connected load amperage .......................... 10.0
Cable Tie
GEA00045