Installation - Gaggenau AH 900761 Operating And Installation Instructions

Table of Contents

Advertisement

Available languages

Available languages

Installation

40
Fig. 15
Fig. 16
16
The hood features an upward blow-out opening.
For laying through the outside wall, we recommend
use of our telescopic wall box TM 150-045.
260
Note:
To prevent the penetration of water, e.g.
condensation or rain water from an uncovered
exhaust air shaft, into the hood, our condensation
collector RV 060- 150 must be fitted in the
proximity of the hood. The condensation collector
must still be accessible after installation.
Circulating air operation
The following parts should have been included if
you decided in favor of circulating air operation of
the hood:
for AH 900-761
Activated charcoal filter KF 900-055
for AH 900-791
Activated charcoal filter KF 900-090
Air baffle LL 010-000
The air baffle is secured on the cabinet front,
blowing out towards the front. The distance
between the hood and the air baffle must be
bridged with a pipe consisting of non-combusting
material. The air out of the baffle must be capable
of flowing back into the room without obstruction.
When using a panel reaching up to the ceiling,
produce an opening in this panel.
Note on wooden front panel:
The hood's handle rail cannot be replaced by a
wooden front panel.