Top Vent Configuration With Vertical Termination - Travis Industries Lopi Northfield Owner's Manual

Direct vent freestanding stove
Table of Contents

Advertisement

22

Top Vent Configuration with Vertical Termination

Use 6-5/8" Diameter Vent
Horizontal sections require a ¼" (6mm) rise every 12" (305mm) of travel.
A maximum of four (4) 45° or 90° elbows may be used. Of these elbows, only one (1) may be a
horizontal elbow (see illustration).
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
positions. NOTE: Restrictor positions are based upon lab tests. The ideal restrictor position may
vary slightly, especially when the termination is near a demarcation line.
Diffuser set to open (stock) position.
Install the intake damper plate.
Install the exhaust restrictor extender plate.
© Travis Industries
Installation
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet
Horizontal elbows are elbows placed between
two horizontal sections of pipe. One 45° or 90°
horizontal elbow is allowed for this configuration.
(for qualified installers only)
Exhaust Restrictor Position #5
Intake Restrictor Position #6
Exhaust Restrictor Position #3
Intake Restrictor Position #4
Exhaust Restrictor Position #2
Intake Restrictor Position #3
Horizontal Elbow
4091120
40' max (12m)
35 feet (10.5m)
30 feet (9m)
25 feet (7.5m)
20 feet (6m)
15 feet (4.5m)
10 feet (3m)
5 feet (1.5m)
0 feet