Light Bulb Replacement - Dimplex LAGUNA LAGFB2 User Manual

Laguna firebox
Table of Contents

Advertisement

MAINTENANCE

LIGHT BULB REPLACEMENT

Allow at least 5 minutes for light bulbs to cool before touching bulbs to avoid accidental burning of skin.
Light bulbs need to be replaced when you notice a dark section of the fl ame or when the clarity and detail
of the log ember bed exterior disappears. There are four bulbs under the log set, which generate the
fl ames and embers, and two bulbs above the log that illuminate the log exterior.
LOWER LIGHT BULB REQUIREMENTS
Quantity of 4 clear chandelier or candelabra bulbs
with an E-14 (small) socket base, 40 watt rating.
DO NOT EXCEED 40 WATTS PER BULB.
HELPFUL HINTS
It is a good idea to replace all light bulbs at one
time if they are close to the end of their rated life.
Group replacement will reduce the number of times
you need to open the unit to replace light bulbs.
Care must be taken when removing the logset as
the logset contains LED's and wires.
TO ACCESS THE LOWER BULB AREA (FIGURE 7)
Please take care when placing fi rebox in mantel (2 person lift)
1. Slide fi rebox out of mantel 50-75mm.
2. Remove 4 Phillips screws from the right side of trim.
3. Slide glass to right side of fi rebox to remove.
4. Pull the front edge of the plastic ember bed or plastic
grate up and forward until the rear tab releases from
the ledge located at the bottom of the mirror.
IMPORTANT:
Only handle the logset by the emberbed.
NOTE: Logset fi ts tightly into fi rebox, so care is necessary
when removing.
5. Set logset in front of fi rebox.
6. Disconnect the logset LED wire harness from unit.
7. Unscrew bulbs counter clockwise.
8. Insert new bulbs.
9. Reconnect the logset LED wire harness.
10. Replace the logset by inserting the front edge of the fi rebox and push down on the rear edge of
the emberbed until it snaps into place. (FIGURE 8)
NOTE: Ensure the logset is installed tightly under the back ledge to prevent light leakage.
11. Slide front glass back into position and attach trim.
UPPER LIGHT BULB REQUIREMENTS
Quantity of 2 clear chandelier or candelabra bulbs with an E-14 (small) socket base, 7 watt rating.
DO NOT EXCEED 7 WATTS PER BULB
TO ACCESS THE UPPER LIGHT BULB AREA (FIGURE 7)
Please take care when placing fi rebox in mantel (2 person lift)
1. Slide fi rebox out of mantel 50-75mm.
2. Remove 4 Phillips screws from right side of trim.
3. Remove trim.
4. Slide glass to the right side of the fi rebox to remove.
5. Remove upper light panel.
6. Upper bulbs located in the upper left and upper right corners of fi rebox.
FIGURE 7
Upper Light
Panel
Logset
LED Wire
Harness
Upper
Bulbs
Front
Glass
Lower
Bulbs
Trim
FIGURE 8
6

Advertisement

Table of Contents
loading

Table of Contents