Maintenance And Service - Heat & Glo RH-36 Series Owner's Manual

Wood burning fireplace installation and operation
Hide thumbs Also See for RH-36 Series:
Table of Contents

Advertisement

3

Maintenance and Service

A. Disposal of Ashes
Frequency:
By:
WARNING! Risk of Fire!
Remove screws,
lift top cover.
Top Cover
Cap
Chimney
Slip
Section
TR344/TR342
Round
Termination Cap
Figure 3.1
Chimney & Termination Cap Cleaning
Remove 4 screws
and lift top pan off.
Cap
Cap
Chase
ST375
Square
Termination Cap
B. Chimney Inspection/Cleaning
Frequency:
By:
-
WARNING! Risk of Fire!
Creosote - Formation and Need for Removal
WARNING! Risk of Fire!
1. Remove the 4 screws.
Remove 2 screws from
2. Remove the screen.
the front and back and
3. Remove the baffle.
lift the top off.
TCT375
TS345/TS345P
Terra Cotta
Square
Termination Cap
Termination Caps
1. Remove (8) screws
2. Lift Top off
TOP
SCREW
DT SERIES
TOP
SCREW
11