Electrical Adjustments
Group/
Item Name
Item
6
Flow Calib Effective Diff 7
7
Flow Calib Effective Diff 8
Group
Flow Clog Threshold
244
0
Flow Clog Threshold 1
1
Flow Clog Threshold 2
2
Flow Clog Threshold 3
3
Flow Clog Threshold 4
4
Flow Clog Threshold 5
5
Flow Clog Threshold 6
6
Flow Clog Threshold 7
7
Flow Clog Threshold 8
10
Flow Inlet Err Threshold1
11
Flow Inlet Err Threshold2
12
Flow Inlet Err Threshold3
13
Flow Inlet Err Threshold4
14
Flow Inlet Err Threshold5
15
Flow Inlet Err Threshold6
16
Flow Inlet Err Threshold7
17
Flow Inlet Err Threshold8
Group
Flow Clog Monitor
246
0
Real Flow Data
1
Ideal Flow Data
2
Flow Difference Data
Clog Detect Flow Difference
3
Data
Warn Detect Flow Difference
4
Data
5
Press Add Data
6
Filter Scroll Timer
7
Air Inlet Err Difference Data
Group
Fan Voltage Adjustment
250
0
Fan 1 Min Adjust (DAC)
1
Fan 1 Max Adjust (DAC)
2
Fan 2 Min Adjust (DAC)
3
Fan 2 Max Adjust (DAC)
4
Fan 3 Min Adjust (DAC)
5
Fan 3 Max Adjust (DAC)
6
Fan 4 Min Adjust (DAC)
7
Fan 4 Max Adjust (DAC)
8
Fan 5 Min Adjust (DAC)
9
Fan 5 Max Adjust (DAC)
10
Fan 6 Min Adjust (DAC)
11
Fan 6 Max Adjust (DAC)
12
Fan 7 Min Adjust (DAC)
13
Fan 7 Max Adjust (DAC)
Group
Fan Option
252
0
Fan Max Switch
1
Safety Switch
2
Fan Manual Switch
3
Fan1 Manual Voltage
4
Fan2 Manual Voltage
5
Fan3 Manual Voltage
6
Fan4 Manual Voltage
7
Fan5 Manual Voltage
8
Fan6 Manual Voltage
9
Fan7 Manual Voltage
10
Angle Data A
11
Angle Data B
12
Press Data
Function
Flow Sensor Calibration Range Diff No.7 [ADC]
Flow Sensor Calibration Range Diff No.8 [ADC]
(Not Memorized )
Flow Sensor Clogged Threshold No.1[ADC]
Flow Sensor Clogged Threshold No.2[ADC]
Flow Sensor Clogged Threshold No.3[ADC]
Flow Sensor Clogged Threshold No.4[ADC]
Flow Sensor Clogged Threshold No.5[ADC]
Flow Sensor Clogged Threshold No.6[ADC]
Flow Sensor Clogged Threshold No.7[ADC]
Flow Sensor Clogged Threshold No.8[ADC]
Flow Sensor Inlet Err Threshold No.1[ADC]
Flow Sensor Inlet Err Threshold No.2[ADC]
Flow Sensor Inlet Err Threshold No.3[ADC]
Flow Sensor Inlet Err Threshold No.4[ADC]
Flow Sensor Inlet Err Threshold No.5[ADC]
Flow Sensor Inlet Err Threshold No.6[ADC]
Flow Sensor Inlet Err Threshold No.7[ADC]
Flow Sensor Inlet Err Threshold No.8[ADC]
(Read only)
Real Flow Data [ADC] (Read only)
Theory Flow Data (Read only)
Flow Difference Data [ADC] (Read only)
Difference Data to judge the Filter Clogged
[ADC] (Read only)
Difference Data to judge the Filter Clogged
Warning [ADC] (Read only)
Add Data by Air Pressure (Read only)
Timer for Filter Scroll [hour] (Read only)
Difference Data to judge the Inlet Error [ADC]
(Read only)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0: Normal operation
1: Fixed Max (13.5V)
Safety Application use
Fan Manual SW (0: Auto 1: Manual)
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
Angle Data A (Read only)
Angle Data B (Read only)
Air Pressure Data (Read only)
-68-
Range
Initial
0 - 1023
300
0 - 1023
300
0 - 1023
111
0 - 1023
135
0 - 1023
159
0 - 1023
183
0 - 1023
211
0 - 1023
235
0 - 1023
251
0 - 1023
274
0 - 1023
159
0 - 1023
201
0 - 1023
251
0 - 1023
303
0 - 1023
363
0 - 1023
412
0 - 1023
447
0 - 1023
466
0 - 1023
-
0 - 1023
-
-1023 - 1023
-
0 - 1023
-
0 - 1023
-
0 - 1023
-
0 - 32767
-
0 - 1023
-
0-255
84
0-255
237
0-255
83
0-255
240
0-255
40
0-255
244
0-255
40
0-255
230
0-255
41
0-255
232
0-255
43
0-255
233
0-255
39
0-255
229
0-1
0
0-6
0
0-1
0
0-145
100
0-145
100
0-145
100
0-145
100
0-145
100
0-145
100
0-145
100
-
-
-
-
-
-
Note