rEaD anD SaVE tHESE inStructionS
warning
to rEDucE tHE riSK oF FirE, ELEctric SHocK, or in-
JurY to PErSonS, oBSErVE tHE FoLLowing:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring (including switch loca-
tion) must be done by a qualified person(s) in accordance
with all applicable codes and standards, including fire-rated
construction.
4. Provide sufficient air for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the combustion equip-
ment standards such as those published by the National
Fire Protection Association (NFPA), the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and local codes.
5. This product may have sharp edges. Be careful to avoid cuts
and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Use only metal ductwork.
9. Do not use this fan with any solid-state speed control device.
10. A s an alternative, this product may be installed with the UL-
approved cord kit designated for the product, following in-
structions packed with the cord kit.
11. This unit must be grounded.
to rEDucE tHE riSK oF a rangE toP grEaSE FirE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ig-
nite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
cooking flaming foods (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for
the size of the surface element.
to register this product,
visit: www.broan.com
For DomEStic cooKing onLY
models QP130Bl • QP130BlC • QP130ss • QP130ssC
QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW
warning
to rEDucE tHE riSK oF inJurY to PErSonS in tHE
EVEnt oF a rangE toP grEaSE FirE, oBSErVE tHE
FoLLowing:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned or
spread the fire.
3. DO NOT USE WATER, including wet dishcloths or towels
- violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
caution
1. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
2. For best capture of cooking impurities, range hood should
be mounted so that the top of the hood is 24"-30" above the
cooking surface.
3. Read specification label on product for information and re-
quirements.
NOTE
If hood is to be installed non-ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
installer: Leave this manual with
Homeowner: cleaning,
maintenance and operating
instructions on page 2.
the homeowner.
Page 

Advertisement

Table of Contents
loading

Summary of Contents for Broan QP130BL

  • Page 1 QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  QP S e ri es to register this product, r a n g e Hood visit: www.broan.com rEaD anD SaVE tHESE inStructionS...
  • Page 2: Cleaning And Maintenance

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  cLEaning & maintEnancE PrEParE HooD Location For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild ROOF CAP 3¼" X 10" or detergent solution on stainless and painted surfaces.
  • Page 3: Prepare The Hood

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  3¼” X 10” WOOD SHIMS (recessed-bottom HorizontaL Ducting cabinets only) 1½" CABINET FRONT " " 4" HORIZONTAL DUCT ACCESS HOLE CABINET BOTTOM 5¼"...
  • Page 4: Install The Hood

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  inStaLL tHE HooD 7” ROUND KNOCKOUT PLATE (also warning remove 3¼” x 10” To reduce the risk of electrical shock, switch power off vertical plate) at service panel. Lock or tag service panel to prevent power from being switched on accidentally. 3¼” x 10” VERTICAL KNOCKOUT 3¼” x 10” PLATE HORIzONTAL...
  • Page 5: Connect The Wiring

    To, ImPlIed WARRANTIes oF meRCHANTABIlITY oR FITNess FoR A PARTICUlAR PURPose. during this one year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY...
  • Page 6: Service Parts

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  SErVicE PartS KEY no. Part no. DEScriPtion 97017727 7” Round Duct Plate (includes mounting hardware) 97017729 Switch Assembly White (includes 2 switches, nameplate, mounting hardware) 97017730 Switch Assembly Black (includes 2 switches, nameplate, mounting hardware) 99526653 Nameplate, White 99526652 Nameplate, Black 97017736 Capacitor Kit (includes wire nuts, mounting screw) 97017753 Non-duct Slide, White (includes mounting hardware)
  • Page 7 QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Hot t e d e Page  cui s i ne de Pour enregistrer ce produit, visitez : www.broan.com Sér i e Q P...
  • Page 8: Nettoyage Et Entretien

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  nEttoYagE Et EntrEtiEn PrÉParation DE L’EmPLacEmEnt DE Pour des raisons de santé, de performance et d’apparence, nettoyez le filtre, le ventilateur et les surfaces graisseuses. Utilisez seulement La HottE un chiffon propre et une solution de détergent doux sur l’acier...
  • Page 9: Préparation De La Hotte

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  conDuit HorizontaL 8,3 X 25,4 cm (3¼ X 10 Po) CALES DE BOIS (armoires à base en 3,8 cm retrait seulement) AVANT DE L’ARMOIRE...
  • Page 10: Installation De La Hotte

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page 0 inStaLLation DE La HottE OUVERTURE RONDE PRÉAMORCÉE DE 17,8 cm aVErtiSSEmEnt (7 po) (enlevez également la plaque pour conduit P our réduire les risques de choc électrique, coupez le vertical de 8,3 x 25,4 cm courant du panneau électrique.
  • Page 11: Garantie

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  raccorD Du cÂBLagE garantiE Garantie limitée de un an CÂBLE GARANTIe dU PRoPRIÉTAIRe: Broan-NuTone garantit à ÉLECTRIQUE l’acheteur original de ses produits que ces derniers seront exempts DE LA MAISON de tout défaut de matériaux et de fabrication pour une période de un...
  • Page 12: Pièces De Rechange

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Page  PiÈcES DE rEcHangE rEPÈrES n° DE PiÈcE DEScriPtion 97017727 Plaque pour conduit rond de 17,8 cm (7 po) (comprend la quincaillerie de montage) 97017729 Ensemble d’interrupteurs blancs (2 interrupteurs, plaque indicatrice, quincaillerie de montage) 97017730 Ensemble d’interrupteurs noirs (2 interrupteurs, plaque indicatrice, quincaillerie de montage) 99526653 Plaque indicatrice, blanche 99526652 Plaque indicatrice, noire 97017736...
  • Page 13 QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Página  campana de Para registrar este producto, cocina serie QP visite: www.broan.com LEa Y conSErVE EStaS inStruccionES SoLamEntE Para cocinar En caSa...
  • Page 14: Limpieza Y Mantenimiento

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Página  LimPiEza Y mantEnimiEnto PrEParE EL Lugar DonDE SE Va a inStaLar Por motivos de desempeño, apariencia y salud, limpie el filtro, el únicamente...
  • Page 15: Prepare La Campana

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Página  conDucto HorizontaL DE CUÑAS DE MADERA 3 ¼ X 10 PuLg. (8.3 X 25.4 cm) (sólo gabinetes de 1 ½ pulg.
  • Page 16: Instale La Campana

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Página  inStaLE La camPana PLACA REDONDA DE AGUJERO CIEGO DE 7 PULG. [17.8 CM] aDVErtEncia también desmonte P ara reducir el riesgo de una descarga eléctrica, desco- la placa vertical de necte el suministro eléctrico al panel de servicio. Bloquee 3 ¼ 10 pulg. el panel de servicio o póngale una etiqueta de seguridad [8.3 x 25.4 cm]) para evitar que alguien conecte accidentalmente la en- ergía eléctrica.
  • Page 17: Conecte El Cableado

    GARANTÍA: Para tener derecho al servicio PrEcauciÓn: Las bombillas podrían estar de garantía, usted debe (a) notificar a Broan-NuTone a la calientes. consulte la información adicional en dirección o al número de teléfono indicado abajo, (b) indicar el los paquetes de bombillas.
  • Page 18: Piezas De Repuesto

    QP130Bl • QP130BlC • QP130ss • QP130ssC QP130WW • QP130WWC • QP136Bl • QP136ss • QP136WW Página  PiEzaS DE rEPuESto cLaVE n.º PiEza n.º DEScriPciÓn 97017727 Placa redonda de 7 pulg. (17.8 cm) (incluye piezas de montaje) 97017729 Montaje de interruptor blanco (incluye 2 interruptores, placa de identificación, piezas de montaje)
  • Page 20 99526629G...

Table of Contents