INSTALLATION & OPERATING MANUAL
The Captiva 600 & 900 are approved to be installed as a zero clearance
firebox and are designed to operate on Natural Gas and Propane (LPG)
gases ONLY. Approval Number GSCS20081.
VERSION 19

Advertisement

Table of Contents
loading

Summary of Contents for Real Flame CAPTIVA

  • Page 1 BALANCED FLUE SPACE HEATER INSTALLATION & OPERATING MANUAL The Captiva 600 & 900 are approved to be installed as a zero clearance firebox and are designed to operate on Natural Gas and Propane (LPG) gases ONLY. Approval Number GSCS20081. VERSION 19...
  • Page 2 WARNING The “Captiva 600 & 900” have a primary safety glass fitted in front of the glass door. This safety glass is fitted to these appliances to reduce the risk of injury from burns and at no time should this glass be permanently removed.
  • Page 3: Table Of Contents

    CONTENTS Contents ........................3 Data Plate .........................4 Zero Clearance introduction ..................5 Dimensions Captiva 600 ..................6 Dimensions Captiva 900 ..................7 Timber frame installation..................8 Vertical venting installation..................10 Tests to be carried out by installer .................11 Servicing and maintenance ...................11 Parts list ........................13 Gas control assembly ....................13 Flue termination (cowls) regulations ..............15...
  • Page 4: Data Plate

    DATA PLATE (Affixed to the base of the unit for reference to gas pressure & consumption) MODEL CAPTIVA 600 SERIAL NO. DATE OF MANUFACTURE GAS TYPE APPROVAL: GSCS20081 NATURAL GAS @ 1.00 kPa Test Pressure Point (High) Injector Size Gas Consumption 1.65 mm...
  • Page 5: Zero Clearance Introduction

    CAPTIVA ZERO CLEARANCE MODEL INTRODUCTION The Real Flame “Captiva” is a log/coal or pebble effect space heater for use with Natural Gas and Propane. The Real Flame warranty will be voided by, and Real Flame disclaims any responsibility for the following actions: •...
  • Page 6: Dimensions Captiva 600

    DIMENSIONS Captiva 600 Captiva 600 Trim FRONT - 4 SIDED FRONT - 3 SIDED...
  • Page 7: Dimensions Captiva 900

    DIMENSIONS Captiva 900 Captiva 900 Trim FRONT - 4 SIDED FRONT - 3 SIDED 1020...
  • Page 8: Timber Frame Installation

    180mm Zero Clearance cowl types • The Captiva balanced flue space heater is a “Zero Clearance” type heater which comes complete in a zero clearance casing. • It can be installed with the flue terminating with a horizontal or vertical cowl to suit the application.
  • Page 9 CAPTIVA ZERO CLEARANCE MODEL (continued) Captiva Zero Clearance Timber Frame Installation (continued) (Recommended only) (Recommended only) IMPORTANT Install unit and fluing before plasterboard. HEATER From hearth Approx 20mm for Frameout Dimensions (in mm) hearth if required. MODEL NOTE: If fire is to be installed off the floor with a 4 sided...
  • Page 10: Vertical Venting Installation

    All flueing must maintain a clearance of 50mm from combustible materials. NOTE: It is imperative for satisfactory operation of the “Captiva” space heater that no flueing components be modified in any way. All components have been manufactured to eliminate the...
  • Page 11: Tests To Be Carried Out By Installer

    CAPTIVA ZERO CLEARANCE MODEL (continued) Tests to be carried out by installer • Check unit for gas leaks. • Ensure that both high and low pressures are set as per the appliance data plate. Refer Page 4 for adjustments and Test pressure points •...
  • Page 12 SERVICING AND MAINTENANCE (continued) Figure (6) Undo bulkhead/burner nut. Figure (7) Remove holding screws from each side of burner. Figure (8) Remove sparker cover from front of Figure (9) Remove front protection mesh by burner and then gently remove burner taking removing screws.
  • Page 13 SERVICING AND MAINTENANCE (continued) Figure (12) Undo the two screws at the front Figure (13) Loosen the wing nuts of each side of the module, then remove the wiring of the valve which will allow the valve to slide harness, the module can then be removed. out.
  • Page 14: Parts List

    PARTS LIST Gas Control Valve Module Box Remote Control Remote Control Module Sparkers Sensor GAS CONTROL ASSEMBLY Inlet Test Adjustment Outet Test Pressure Point for High Pressure Point Gas Inlet Gas Outlet Adjustment for Low...
  • Page 15: Flue Termination (Cowls) Regulations

    CAPTIVA FLUE TERMINATION (COWLS) REGULATIONS Balanced Flue...
  • Page 16: Remote Control Operating Guide

    This should be read before servicing commences. The Captiva 600 & 900 are controlled completely by the use of the remote control; this remote can be used either as a manual operation or an auto operation.
  • Page 17 When setting the programs have the remote near the unit to ensure the remote can communicate with the control (Located in the bottom of the heater.) The Captiva will operate through the remote either in Manual Mode or Auto Mode, below is a sample of each: Example of Manual Operation Set the thermostat to desired Set temperature e.g.
  • Page 18 REMOTE CONTROL OPERATING GUIDE (continued) In Auto mode, the RF thermostat will control the flame and the fan according to the programmed times and temperature. The flame can be programmed to turn on or off, or change the required temperature. The switch off and on sequence operate as per manual operation, detailed above.
  • Page 19: Optional Marble Hearth And/Or Margin Set

    1840 Marble Margin Set Installation Procedure Install Captiva with trim removed. Install marble up to the fire flange. Use liquid nails to fix to wall. Marble should look like the diagram below once it has been installed and before mantelpiece has been attached.
  • Page 20: Optional Mantelpiece

    MODEL 600 FLUSH 1695 1240 900 FLUSH 1840 1240 1140 600 BOX 1695 1240 900 BOX 1840 1240 Captiva Flush Firebox Plaster Marble Trim Mantel Captiva Boxed Plaster 200 x 200mm Boxed mantel marble block Firebox Trim Marble hearth Marble infill option...
  • Page 21: Electrical Diagram

    ELECTRICAL DIAGRAM...
  • Page 24: Real Flame Contact Information

    REAL FLAME PTY LTD ABN 76 006 311 155 Head Office/Factory/Showroom 1340 Ferntree Gully Rd. Scoresby Vic 3179 Ph: (03) 8706 2000 Fax: (03) 8706 2001 E-mail: info@realflame.com.au Richmond - VIC Showroom 300 Swan St. Richmond Vic 3121 Ph: (03) 9428 4443 Fax: (03) 9428 4445 Dandenong - VIC Showroom 9 Lonsdale St.

This manual is also suitable for: