Customer : Keep these installation instructions for future reference and the local electrical inspector’s use. Customer Service Information If the unit requires service or you have questions or problems with installation, contact your Dacor dealer or the Dacor Customer ®...
Use common sense and caution when WARNING installing, maintaining or operating this or any other appliance. Hazards or unsafe practices that COULD result in severe Always contact Dacor about problems or conditions you do not personal injury or death. understand. READ AND SAVE THESE...
Page 4
Important Safety Instructions General Safety Precautions (cont.) WARNING • Before performing any type of service or installation, make sure that the gas supply and electric power to the range are off. • NEVER block or cover any slots, holes or passages anywhere inside the oven or on the outside of the range or cover an oven rack with materials such as aluminum foil.
Refer to the data label, or the table below, for electrical requirements. Accessory 3” (76mm) Side Panels (Dacor Model No. AESP03) EGR30, ERD30, ERD60 Overall Dimensions - Side View Total Electrical Connected Manifold Min.
Access to the remote circuit breaker • The range may be installed flush to the rear wall. Dacor panel/fuse box with the range in place must also be allowed highly recommends installing a non-combustible material on for in the installation.
Page 7
29 1/4" (743mm) 13/32" (10mm) 30 1/16" (764mm) 30 1/16" (764mm) (10mm) ERD/EGR30 Slide-In, Self-Rimming ERD/EGR30 Slide-In, Self-Rimming Installation using Installation with Side Panels and 3” Side Panels (Model No. AESP03), Backguard Removed Backguard Removed. Top View Top View Vertical...
Lens pry stick (selected models) Installing the Anti-Tip Bracket Hinge Catch (Models ERD30 and EGR30 Only) 30” ranges require an anti-tip device. Before installing the range, you must locate the anti-tip bracket in the product packaging and secure it to the floor as shown below.
Installation Instructions Electrical Connection of ERD Series Ranges Cable from power supply (continued) Connecting to a Three-Wire Electrical System Junction (where local codes permit) WARNING Do not connect the green appliance wire to the neutral (white) GREEN supply wire unless local building codes permit. WHITE WHITE Make sure power to the junction box is switched off at the...
On models ERD30 and EGR30, attach the anti-tip leveler to grill. Open the oven door and remove the inlet air cooling grill for the range as shown below if it is not already attached.
Repeat the above bake test or burner ignition test. If the appliance still does not work, contact an authorized Dacor service company at (800) 793-0093. Do not attempt to repair the appliance yourself. Dacor is not responsible for service required to correct a faulty installation.