Customer: Keep these installation instructions for future reference and the local electrical inspector's use. If the unit requires service or you have questions or problems with installation, contact your Dacor ® dealer or the Dacor Customer Service Team. Dacor Customer Service Team (800) 793-0093 (U.S.A.
Use common sense and caution when installing, maintaining or operating this or any other appliance Hazards or unsafe practices that COULD result in severe Always contact Dacor about problems or conditions you do not personal injury or death understand...
Page 4
General Safety Precautions (cont.) Before performing any type of service or installation, make sure that the gas supply and electric power to the range are off • • NEVER block or cover any slots, holes or passages anywhere inside the oven or on the outside of the range or cover an oven rack with materials such as aluminum foil Doing so blocks airflow through the oven and cooktop and may cause carbon monoxide poisoning or fire •...
Refer to the data label, or the table below, for electrical requirements. Accessory 3" (76mm) Side Panels (Dacor Model No. AESP03) EGR30, ERD30, ERD60 Overall Dimensions - Side View Total Electrical Connected Manifold Min.
Access to the remote circuit breaker • The range may be installed flush to the rear wall. Dacor panel/fuse box with the range in place must also be allowed highly recommends...
Page 7
29 1/4" (743mm) 13/32" (10mm) 30 1/16" (764mm) (1Omm) 30 1/16" (764mm) ERD/EGR30 Slide-In, Self-Rimming ERD/EGR30 Slide-In, Self-Rimming Installation using Installation with Side Panels and 3" Side Panels (Model No. AESP03), Backguard Removed Backguard Removed. Top View Top View Vertical...
Pull the door away from the oven while continuing to lift. (;8mm) 3 7/8" 1 1/2" (prom) F,oo __ 3O 1/16" (763m) Min. Installation of ERD30/EGR30 Anti-Tip Bracket Top View _SCD_...
Electrical Connection of ERD Series Ranges Cable from power supply (continued) Connecting to a Three-Wire Electrical System (where local codes permit) Make sure power to the junction box is switched off at the circuit breaker or fuse box. Connect the green and white appliance wires to the neutral (white) supply wire in the junction box.
On models ERD30 and EGR30, attach the anti-tip leveler to grill. Open the oven door and remove the inlet air cooling grill for the range as shown below if it is not already attached.
Repeat the above bake test or burner ignition test. If the appliance still does not work, contact an authorized Dacor service company at (800) 793-0093. Do not attempt to repair the appliance yourself. Dacor is not responsible for service required to correct a faulty installation. _::_acar...