Revised
06/25/08
28 1/2" (724mm)
27" (686mm)
26" (660mm)
24 3/8" (619mm)
1 9/16"
(40mm)
Finished Side Panel
Accessory 3" (76mm) Side Panels
(Dacor Model No. AESP03)
ERD/EGR30, ERD60 ovERALL DImENsIoNs
sIDE vIEW
NOTES:
1.
Utilities may be located in the lower left corner of
the adjacent right cabinet. (Recommended)
2.
Contact your local building department to verify
compliance with local code interpretation.
3.
Two electrical circuits and gas supplies required.
Web: http://www.Dacor.com
Corporate Phone: 800-793-0093
ERD60
60" Wide,
Epicure
Handle
Front Edge of Bullnose
Face of Control Panel/Oven Door
Rear of Control Panel/Oven Door
6" (152mm) Backguard
When Backguard and
Side Panels are
removed, the overall
depth decreases
by 1" (25mm)
37"
(940mm)
to
35 3/4"
(908mm)
Dacor
®
Model No.
ERD60
240 Vac, 4-wire, 60 Hz,
ERD60LP
30 Amp (Breaker) X2
*Two separate dedicated circuits are required, one for left and one for the right side of the range.
Range
®
◊
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
◊
This appliance must be installed in accordance with the
accompanying installation instructions.
6" (152mm)
Backguard
Power Cords
Total
Dedicated Circuit*
Connected
Required
Load
4.1 kW
(21Amp) X2
ELEctRIcAL AND GAs sUPPLy REqUIREmENts
Specifications are subject to change without notice.
See installation instructions for additional details.
PLANNING
GUIDE
1/2
waRNiNg
60" (1524mm)
Factory installed 3/4" regulators
(1/2" supply ok)
REAR vIEW
gas
Manifold
Min. gas Supply
Type
Pressure
Natural
5" Water Column
6" Water Column
Liquid
10" Water Column
11" Water Column
Propane
Pressure
5.7