La-Z-Boy Spas Premier Owner's Manual page 43

Table of Contents

Advertisement

Problem
Cause
Low/no jet
Air lock
pressure
Dirty filter
Closed jets
Closed
valves
ACV* open
Low water
Monitor
Monitor does
not pop up
mechanism
broken
Moved my spa
Wiring error
and now it
at GFCI
doesn't work
No power to
spa
No flow
Closed jets
ACV open
Nothing works
Breaker has
tripped
pH changed
Total
suddenly
alkalinity
No power to
Pump not
running
spa
Pump runs
Normal
continuous
Sanitation
Improper
(chlorine) level
level for use
too high/low
Improper
Sanitation
(water) too
filter cycle
time
murky
Scaling
Hardness
level
Speaker does
Speaker
not pop up
mechanism
broken
For HELP, call La-Z-Boy
Solution
Bleed air from the system (page 41)
Check and clean or replace filter
Open all jets by turning CCW
Open all T-handle shutoff valves on heater and
pumps
Close air control valves
Fill spa 1" above all jets
Replace monitor
Check Neutral wiring of GFCI (see diagrams on
pages 13 - 14)
Reset circuit breakers on GFCI panel and main
circuit breaker panel
Open jets
Close ACV
Check and reset breaker. If problem persists, check
for loose electrical connections. Check for Neutral
wiring error at GFCI.
Check total alkalinity level and adjust if necessary
(see page 21)
Reset circuit breakers on GFCI panel and main
circuit breaker panel
Normal
Adjust level for use
Increase filter cycle time
Adjust hardness level
Replace speaker
Spas at 1.800.465.2933.
®