Listing Information - Lopi Heritage Bay DV Owner's Manual

Freestanding direct-vent stove natural gas or propane residential or mobile home
Table of Contents

Advertisement

The safety label can be found inside the right side panel. A copy is shown below.
Tested &
Listed by
Report No. 028-S-14-5
Tested and certified by OMNI-Test, Inc. to the following standards:
USA: ANSI Z21.44-1992 Gas-Fired Gravity and Fan type Direct-Vent Wall Furnace, applicable sections of Z21.11.1-1991 Gas-Fired Vented Room Heaters and
UL 307b Gas Burning Heating Appliances for Mobile Homes and Recreational Vehicles.
CANADA: CAN 1-2.19-M81 Gas-Fired Direct-Vent Wall Furnace, CGA IR41 Direct-Vent Gas Fireplace, CGA IR55 additional requirements for Direct-Vent
Fireplaces, and CAN/CGA 2.17-M91 "Gas-Fired Appliances for use at High Altitudes".
Must be installed in accordance with all local codes, if any; if not, follow ANSI Z223.1-1992 and NFPA 54(88). Installation in Manufactured or Mobile Homes must
conform with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280; In Canada, CSA Z240.4 and Gas-Equipped Recreational
Vehicles and Mobile Housing. This model is designed to operate on natural gas, or propane (LP). This appliance uses a millivolt-type control system consisting of
a gas control valve/regulator, a standing pilot burner assembly, a thermopile, a piezo ignitor, and the ON/OFF switch. THIS UNIT DOES NOT REQUIRE 110 VOLT
POWER TO OPERATE. All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure.
This appliance may be installed in Manufactured Housing only after the home is site located.
WARNINGS:
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the information in the owner's and installation
manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier.
Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present. The control compartment, the
burner compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.
This room heater is a Direct-Vent Gas-Fired appliance. DO NOT burn wood or other material in this heater.
Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or clothing ignition.
Young children should be carefully supervised at all times when they are in the same room as the appliance.
CAUTION:
All safety screen or guard components removed for servicing, must be replaced prior to operating the appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Risk of electrical shock. Switch the household breaker off or remove fuse before servicing unit.
Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior (direct discharge only without duct connection).
Minimum Clearances to
Combustibles
Unit to Sidewall . . . . . . . . .
Unit to Backwall . . . . . . . . .
Unit to Cornerwall . . . . . . .
Front of Unit . . . . . . . . . . . .
Alcove Min. Height . . . . . .
Alcove Max Depth . . . . . . .
Alcove Min Width . . . . . . . . 43-3/8" 1100
Manufacture
Date:
Beaverton,
OR. USA
Input Rate on "HI" (BTU/Hr) ........... 40,000 40,000
IN
MM
Input Rate on "LO" (BTU/Hr) .......... 22,000 19,000
8"
200
Main Burner Orifice (DMS)..............
3"
75
3"
75
36"
910
This room heater is equipped at the factory for use with natural gas. If conversion to propane (LP) fuel is desired the
60"
1520
optional factory conversion kit must be used.
48"
1220
Blower Electrical Rating: 115 V., 1.5 Amps, 60 Hz FAN TYPE VENTED CIRCULATOR
1997
Jan.
Apr.
1998
Feb.
May
1999
Mar.
Jun.
Heritage Bay
Listed Gas-Fired
Direct Vent Wall Furnace
L.P.
N.G.
#49
#31
Jul.
Oct.
Aug.
Nov.
Sep.
Dec.
L
I
ISTING
NFORMATION
Minimum Inlet Pressure (inches W.C.) ..............
Maximum Inlet Pressure (inches W.C.) .............
Manifold Pressure on "HI" (inches W.C.).......... 10.5" 3.5"
Manifold Pressure on "LO" (inches W.C.).........
10850 117th Pl. N.E. Kirkland, WA 98033
P
27
AGE
L.P. N.G.
11"
5"
13"
8"
2.7"
.9"
IGN